Back to Search
Start Over
Evaluation of intraoral digital impressions for obtaining gingival contour in the esthetic zone: accuracy outcomes
- Source :
- Clinical Oral Investigations. 24:1401-1410
- Publication Year :
- 2019
- Publisher :
- Springer Science and Business Media LLC, 2019.
-
Abstract
- To assess the accuracy of intraoral digital impressions for gingival contour captured in the esthetic zone in vivo.Five participants with full upper dentition were recruited. For each participant, three scans were taken using two intraoral scanning (IOS) systems (3Shape TRIOS Color, TRC; CEREC Omnicam, OC) respectively; three conventional impressions (CIs) were taken using vinyl polysiloxane materials. The CIs of all participants were casted and then digitized with a model scanner (IScan D103i, Imetric). Precision was evaluated by superimposing three repeated STL datasets per participant within each group and calculating the (90th-10th)percentile/2 values. The CIs were the reference for evaluating the level of system error of the two IOS systems from the true value. Digital models from CI and each IOS group were superimposed and (mean positive deviation-mean negative deviation)/2[mean negative deviation, mean positive deviation] were calculated to assess trueness level of the two IOS systems.For the soft tissue acquisition, precision results of each group were 45.10 ± 12.54 μm in TRC, 66.04 ± 13.46 μm in OC, and 63.66 ± 17.19 in CI (TRC vs OC, p0.001; TRC vs CI, p = 0.001; OC vs CI, p = 0.66). Trueness results were 80.12 ± 8.69[- 112.10 ± 9.88, 48.13 ± 13.79] μm in TRC and 82.70 ± 8.85[- 121.41 ± 15.40, 43.98 ± 11.86] μm (p0.05).In dentate situations, the two tested IOS systems achieved a clinically satisfying accuracy for capturing gingival contour in anterior maxilla, with a comparable or superior precision to the CI. TRC achieved a similar trueness and a higher precision level compared with OC.Intraoral digital impressions could be a recommended method for recording 3-dimensional gingival contour in the esthetic zone.
- Subjects :
- Orthodontics
Percentile
Dental Impression Technique
Anterior maxilla
Gingiva
030206 dentistry
Esthetics, Dental
Models, Dental
03 medical and health sciences
Negative deviation
Dental Arch
Imaging, Three-Dimensional
0302 clinical medicine
Upper dentition
CEREC
030220 oncology & carcinogenesis
Computer-Aided Design
Humans
General Dentistry
Mathematics
System error
Subjects
Details
- ISSN :
- 14363771 and 14326981
- Volume :
- 24
- Database :
- OpenAIRE
- Journal :
- Clinical Oral Investigations
- Accession number :
- edsair.doi.dedup.....902481e4084bb97b0cf32da18f9fd01d
- Full Text :
- https://doi.org/10.1007/s00784-019-03105-6