Back to Search Start Over

Enflurane as an internal standard in monitoring halogenated volatile anaesthetics by headspace gas chromatography-mass spectrometry

Authors :
Antonio Accorsi
Simona Valenti
Francesco Saverio Violante
Giovanni Battista Raffi
Anna Barbieri
ACCORSI A
VALENTI S
BARBIERI A
RAFFI GB
VIOLANTE FS
Source :
Journal of chromatography. A. 985(1-2)
Publication Year :
2003

Abstract

Recently. we proposed the use of a run-only headspace-GC-MS method for the biological monitoring of ppb concentrations of unmodified volatile anaesthetics (isoflurane, sevoflurane and halothane, plus nitrous oxide) in post-shift urine of operating theatre personnel. The adoption of enflurane (a volatile anaesthetic no longer used in clinical practice) as a poper and viable internal standard improves intra-day and inter-day accuracy in halide quantitation, providing a GC-MS reference method useful in the practice of biomonitoring of exposure of operating theatre personnel to modern volatile anaesthetics (isoflurane. sevoflurane, halothane).

Details

ISSN :
00219673
Volume :
985
Issue :
1-2
Database :
OpenAIRE
Journal :
Journal of chromatography. A
Accession number :