Back to Search
Start Over
The Beamline for the Second Axis of the Dual Axis Radiographic Hydrodynamic Test Facility
- Publication Year :
- 1999
-
Abstract
- During normal DARHT II operation, the beam exiting the accelerator will be well characterized by its nominal design parameters of 20-MeV, 2000-Amperes, 2-/spl mu/sec-pulse length, and 3 cm-mr unnormalized emittance. Normal operation will have the beam delivered to a beam dump via several DC magnets. A 2-way kicker magnet is used to deflect portions of the beam into the straight ahead beamline leading to either a diagnostic beamline or to the converter target beamline. During start up and or beam development periods, the beam exiting the accelerator may have parameters outside the acceptable range of values for normal operation. The Enge beamline must accommodate this range of unacceptable beam parameters, delivering the entire 80 KiloJoule of beam to the dump even though the energy, emittance, and/or match is outside the nominal design range.
Details
- Language :
- English
- Database :
- OpenAIRE
- Accession number :
- edsair.doi.dedup.....939c197d0752d28d0da19a0fceb3f02c