Back to Search
Start Over
Infarct density distribution by MRI in the porcine model of acute and chronic myocardial infarction as a potential method transferable to the clinic
- Source :
- Europe PubMed Central, International Journal of Cardiovascular Imaging, 30(5), 937-948
- Publication Year :
- 2014
-
Abstract
- To study the feasibility of a myocardial infarct (MI) quantification method [signal intensity-based percent infarct mapping (SI-PIM)] that is able to evaluate not only the size, but also the density distribution of the MI. In 14 male swine, MI was generated by 90 min of closed-chest balloon occlusion followed by reperfusion. Seven (n = 7) or 56 (n = 7) days after reperfusion, Gd-DTPA-bolus and continuous-infusion enhanced late gadolinium enhancement (LGE) MRI, and R1-mapping were carried out and post mortem triphenyl-tetrazolium-chloride (TTC) staining was performed. MI was quantified using binary [2 or 5 standard deviation (SD)], SI-PIM and R1-PIM methods. Infarct fraction (IF), and infarct-involved voxel fraction (IIVF) were determined by each MRI method. Bias of each method was compared to the TTC technique. The accuracy of MI quantification did not depend on the method of contrast administration or the age of the MI. IFs obtained by either of the two PIM methods were statistically not different from the IFs derived from the TTC measurements at either MI age. IFs obtained from the binary 2SD method overestimated IF obtained from TTC. IIVF among the three different PIM methods did not vary, but with the binary methods the IIVF gradually decreased with increasing the threshold limit. The advantage of SI-PIM over the conventional binary method is the ability to represent not only IF but also the density distribution of the MI. Since the SI-PIM methods are based on a single LGE acquisition, the bolus-data-based SI-PIM method can effortlessly be incorporated into the clinical image post-processing procedure.
- Subjects :
- Gadolinium DTPA
Male
Pathology
medicine.medical_specialty
Swine
Myocardial Infarction
Contrast Media
Myocardial infarct quantification
computer.software_genre
Article
Random Allocation
Magnetic resonance imaging
Myocardial infarct heterogeneity
Voxel
hemic and lymphatic diseases
Percent infarct mapping
Image Processing, Computer-Assisted
Animals
Medicine
Late gadolinium enhancement
Radiology, Nuclear Medicine and imaging
cardiovascular diseases
Myocardial infarction
Cardiac imaging
Chronic myocardial infarction
Staining and Labeling
medicine.diagnostic_test
business.industry
medicine.disease
Disease Models, Animal
Density distribution
Balloon occlusion
Cardiology and Cardiovascular Medicine
Nuclear medicine
business
computer
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Journal :
- Europe PubMed Central, International Journal of Cardiovascular Imaging, 30(5), 937-948
- Accession number :
- edsair.doi.dedup.....9407730dbc307077275ca08ff5371e85