Back to Search
Start Over
PIV Measurement and Numerical Analysis of a New Refrigeration Compartment of a Refrigerator
- Source :
- Annals of the New York Academy of Sciences. 972:260-264
- Publication Year :
- 2002
- Publisher :
- Wiley, 2002.
-
Abstract
- A new cooling duct system was developed in order to increase the refrigerator performance in terms of uniform temperature distribution particle image velocimetry (PIV) and the commercial software FLUENT was used to compare the performance of the conventional cooling system with the new cooling system. The new cooling system effectively cooled the door basket region, thus increasing the uniformity of the temperature distribution in the refrigeration compartment.
- Subjects :
- Commercial software
Materials science
General Neuroscience
Numerical analysis
Temperature
Refrigerator car
Thermodynamics
Refrigeration
Mechanical engineering
Equipment Design
Models, Theoretical
General Biochemistry, Genetics and Molecular Biology
Kinetics
History and Philosophy of Science
Particle image velocimetry
Water cooling
Fluent
Duct (flow)
Subjects
Details
- ISSN :
- 17496632 and 00778923
- Volume :
- 972
- Database :
- OpenAIRE
- Journal :
- Annals of the New York Academy of Sciences
- Accession number :
- edsair.doi.dedup.....942be98a41b26435ae5548926b78860c
- Full Text :
- https://doi.org/10.1111/j.1749-6632.2002.tb04582.x