- Background: Hardness is considered an important parameter for evaluating the clinical performance of dental implant bone drills. It is connected to the chemical composition, microstructure conformation and manufacture of the surgical drills. Methods: Microstructure of five dental implant drills using scanning electronic microscopy (SEM) integrated with energy dispersive X-ray spectrometry. Vickers microhardness was measured using a CV 2000 microhardness tester with an indentation force of 500 g. Results: Composition of the implant drills was typical of martensitic stainless steel (MSS). The drills contained 13%&ndash<br />17% of Cr<br />Mo, Si and Mn were present as minor ligands. The examined bone drills showed different external surface conformation and hardness in relation to the different industrial production processes. A rougher external surface and a higher hardness value are characteristics of the surgical bone drills produced by hot forming<br />the implant drills produced by machining showed mailing lines on their external surface and a lower hardness. Conclusions: Different compositions and treatments were used by the manufacturers to improve the hardness of the external layer of the dental implant drills making them prone to a diverse heat generation during the implant site preparation.
- Subjects :
- musculoskeletal diseases
Materials science
medicine.medical_treatment
education
02 engineering and technology
Martensitic stainless steel
engineering.material
Indentation hardness
lcsh:Technology
Article
Microstructural surface analysis
03 medical and health sciences
0302 clinical medicine
Drill hardne
Machining
drill hardness
Indentation
medicine
otorhinolaryngologic diseases
General Materials Science
Composite material
Dental implant
lcsh:Microscopy
lcsh:QC120-168.85
lcsh:QH201-278.5
lcsh:T
030206 dentistry
021001 nanoscience & nanotechnology
Microstructure
equipment and supplies
lcsh:TA1-2040
Heat generation
engineering
Bone drill chemical composition
lcsh:Descriptive and experimental mechanics
Implant
lcsh:Electrical engineering. Electronics. Nuclear engineering
Dental implant drill
0210 nano-technology
lcsh:Engineering (General). Civil engineering (General)
lcsh:TK1-9971
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Journal :
- Materials, Vol 12, Iss 11, p 1866 (2019), Materials, Volume 12, Issue 11
- Accession number :
- edsair.doi.dedup.....944553f25eb81861808d500ae69387a5