Performance of F101 radiation resistant lead glass shower counters
- Source :
- Nuclear Instruments & Methods in Physics Research Section A-Accelerators Spectrometers Detectors and Associated Equipment, 378(1-2), 155-161. Elsevier, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment, 378. Elsevier, Airapetian, A & van den Brand, J F J 1996, ' Performance of F101 Radiation Resistant Lead Glass Shower Counters. ', Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment, vol. 378, pp. 155 . https://doi.org/10.1016/0168-9002(96)00443-3
- Publication Year :
- 1996
- Publisher :
- Elsevier BV, 1996.
-
Abstract
- The performance of F101 lead glass as a Cherenkov radiation material was studied. A 3 x 3 array of 9 x 9 cm(2) and 50 cm length counters showed an energy resolution of approximate to 5.0%/root E(GeV), good linearity in the energy range from 1 to 25 GeV and pi(-)/e rejection of approximate to 4 x 10(-4).
- Subjects :
- Physics
Nuclear and High Energy Physics
Range (particle radiation)
Radiation resistant
business.industry
Astrophysics::High Energy Astrophysical Phenomena
Resolution (electron density)
Linearity
Nuclear physics
Lead glass
Optics
DESIGN
ELECTROMAGNETIC CALORIMETER
visual_art
visual_art.visual_art_medium
SPECTROMETER
High Energy Physics::Experiment
business
Instrumentation
Cherenkov radiation
Subjects
Details
- ISSN :
- 01689002
- Volume :
- 378
- Database :
- OpenAIRE
- Journal :
- Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Accession number :
- edsair.doi.dedup.....978b5949dc954145e5f5366fe6440670
- Full Text :
- https://doi.org/10.1016/0168-9002(96)00443-3