Feasibility study of navigated endoscopy for the placement of high dose rate brachytherapy applicators in the esophagus and lung
- Source :
- Medical Physics. 47:917-926
- Publication Year :
- 2020
- Publisher :
- Wiley, 2020.
-
Abstract
- Purpose To evaluate the electromagnetic (EM) tracking of endoscopes and applicators as a method of positioning a high dose rate (HDR) luminal applicator. Method An anatomical phantom consisting of a rigid trachea and flexible esophagus was used to compare applicator placement measurements using EM tracking vs the traditional method using two-dimensional (2D) fluoroscopy and surface skin markers. The phantom included a tumor in the esophagus and several pairs of optically visible points inside the lumen that were used to simulate proximal and distal ends of tumors of varying lengths. The esophagus tumor and lung points were visible on a computed tomography (CT) image of the phantom, which was used as ground truth for the measurements. The EM tracking system was registered to the CT image using fiducial markers. A flexible endoscope was tracked using the EM system and the locations of the proximal and distal ends of the tumor identified and this position recorded. An EM-tracked applicator was then inserted and positioned relative to the tumor markings. The applicator path was mapped using the EM tracking. The gross tumor length (GTL) and the distance between the first dwell position and distal edge of tumor (offset) were measured using the EM tracking and 2D fluoroscopy methods and compared to the same measurements on the CT image. Results The errors in GTL using EM tracking were on average -0.5 ± 1.7 mm and 0.7 ± 3.6 mm for esophagus and lung measurements, similar to errors measured using the 2D fluoroscopy method of -0.9 ± 1.2 mm and 3.4 ± 4.4 mm. Offset measurements were slightly larger while using EM tracking relative to the fluoroscopy method but these were not statistically significant. Conclusions Electromagnetic tracking for placement of lumen applicators is feasible and accurate. Tracking of the endoscope that is used to identify the proximal and distal ends of the tumor and of the applicator during insertion generates accurate three-dimensional measurements of the applicator path, GTL and offset. Guiding the placement of intraluminal applicators using EM navigation is potentially attractive for cases with complex insertions, such as those with nonlinear paths or multiple applicator insertions.
- Subjects :
- Lung Neoplasms
Materials science
Esophageal Neoplasms
Endoscope
medicine.medical_treatment
Brachytherapy
Lumen (anatomy)
Computed tomography
Radiation Dosage
Imaging phantom
030218 nuclear medicine & medical imaging
03 medical and health sciences
0302 clinical medicine
medicine
Humans
Fluoroscopy
Esophagus
medicine.diagnostic_test
Phantoms, Imaging
business.industry
Radiotherapy Dosage
General Medicine
High-Dose Rate Brachytherapy
Endoscopy
medicine.anatomical_structure
030220 oncology & carcinogenesis
Feasibility Studies
Esophagoscopy
Tomography, X-Ray Computed
Fiducial marker
Dose rate
Nuclear medicine
business
Subjects
Details
- ISSN :
- 24734209 and 00942405
- Volume :
- 47
- Database :
- OpenAIRE
- Journal :
- Medical Physics
- Accession number :
- edsair.doi.dedup.....9919a7033753fcbd14e06527e5fffca4
- Full Text :
- https://doi.org/10.1002/mp.13997