Back to Search Start Over

Development and validation of an LC‐MS/MS method for quantifying nine antimicrobials in human serum and its application to study the exposure of Chinese pregnant women to antimicrobials

Authors :
Yanhong Zhai
Zhifeng Pan
Zheng Cao
Min Shen
Ying Liu
Xiaofei Yue
Youran Li
Source :
Journal of Clinical Laboratory Analysis
Publication Year :
2020
Publisher :
Wiley, 2020.

Abstract

Background To study the prevalence of the exposure of pregnant women to antimicrobials, a sensitive and reliable liquid chromatography‐tandem mass spectrometry (LC‐MS/MS) method was developed and validated to determine nine antimicrobials, namely sulfadimidine, sulfapyridine, sulfadiazine, sulfathiazole, ofloxacin, ciprofloxacin, norfloxacin, tetracycline, and lincomycin, in human serum. Methods The sample preparation procedure included protein precipitation followed by a cleanup step with solid phase extraction (SPE). Separation was carried out using a CORTECS T3 column (100 × 2.1 mm, 2.7 µm) by gradient elution with a runtime of 8.0 min. Detection was performed on a triple quadruple tandem mass spectrometer with scheduled multiple reaction monitoring (sMRM) in positive ion scan mode. Results The calibration curves were linear over the concentration range of 0.5–50 ng/ml, and the limit of quantitation was between 0.01 and 0.2 ng/ml. For each level of quality control samples, the inter‐ and intra‐assay precision values were less than 12.0%, and the accuracy ranged from 86.1% to 109.0%. No significant matrix effect or carryover was observed. The antimicrobials of interest were stable under all investigated conditions. The validated method was applied to analyze clinical samples from pregnant women in China, and 10 out of 500 samples showed the presence of antimicrobial residues. Moreover, compared with the time‐resolved fluoro‐immunoassay (TRFIA) method, the developed method showed greater sensitivity and specificity. Conclusion This study provides a simple and rapid LC‐MS/MS method for the simultaneous measurement of nine antimicrobials in serum samples, which could be a useful tool in clinical utilization.<br />We proposed a simple SPE LC‐MS/MS method for the analysis of nine antimicrobials in serum. The elaborated method was applied to investigate the exposure of antimicrobials in Chinese pregnant women, and the results have been compared with those obtained from TRFIA method.

Details

ISSN :
10982825 and 08878013
Volume :
35
Database :
OpenAIRE
Journal :
Journal of Clinical Laboratory Analysis
Accession number :
edsair.doi.dedup.....9a844712ebcec7d2827fe067fd1c8b51
Full Text :
https://doi.org/10.1002/jcla.23658