Back to Search
Start Over
Comparison of Assessment of Native Coronary Arteries by Standard Versus Three-Dimensional Coronary Angiography
- Source :
- The American Journal of Cardiology. 102:272-279
- Publication Year :
- 2008
- Publisher :
- Elsevier BV, 2008.
-
Abstract
- Vessel foreshortening is a major limitation of standard coronary angiography due to the 2-dimensional representation of 3-dimensional structures. Three-dimensional models may overcome it. The aim of this study was to compare measurements of coronary segments from quantitative coronary angiography (QCA) in an operator-selected "working view" of standard 2-dimensional coronary angiography with those from 3-dimensional coronary angiography (3D-CA) reconstruction models, which are automatically generated from software applied to rotational coronary angiographic acquisitions. Patients who underwent percutaneous coronary intervention were considered. Two or 3 segments of the artery needing treatment were prespecified, using bifurcations as edges. The operator selected a working view from standard angiography as the view best representing each segment. Rotational angiography was performed, allowing 3-dimensional reconstruction of the selected segments. Additionally a marker guidewire (with 4 markers 10 mm away from one another at the distal tip) was used to further measure segment length, and it was considered the "gold standard" reference. In 36 patients, 81 segments from 12 left anterior descending, 12 circumflex, and 12 right coronary arteries were evaluated. Three-dimensional coronary angiography was always feasible. Although reference vessel diameter was not different between 3D-CA and QCA (p0.05), segment length measurements were on average 2.3 +/- 2.5 mm longer with 3D-CA than with QCA (p0.001) and 0.4 +/- 1.8 mm longer than with marker guidewire measurement (p = 0.047). Marker guidewire measurements were 1.9 +/- 2.8 mm longer than QCA measurements (p0.001). According to Bland-Altman plots, 3D-CA and marker guidewire measurements had the best agreement. In conclusion, 3-dimensional coronary modeling is highly feasible and yields more accurate assessments of the lengths of coronary segments than standard QCA.
- Subjects :
- Adult
Male
Models, Anatomic
medicine.medical_specialty
medicine.medical_treatment
Coronary Angiography
Imaging
Imaging, Three-Dimensional
Models
Internal medicine
80 and over
medicine
Humans
Circumflex
Adult, Aged, Aged
80 and over, Coronary Angiography, Female, Humans, Imaging
Three-Dimensional, Male, Middle Aged, Models
Anatomic, Software
Aged
Aged, 80 and over
medicine.diagnostic_test
business.industry
Anatomic
Percutaneous coronary intervention
Gold standard (test)
Middle Aged
Coronary arteries
medicine.anatomical_structure
Rotational angiography
Three-Dimensional
Angiography
Circulatory system
Cardiology
Female
Radiology
Cardiology and Cardiovascular Medicine
business
Software
Artery
Subjects
Details
- ISSN :
- 00029149
- Volume :
- 102
- Database :
- OpenAIRE
- Journal :
- The American Journal of Cardiology
- Accession number :
- edsair.doi.dedup.....9b4d3a587b67bb53aff9592df53dfa53
- Full Text :
- https://doi.org/10.1016/j.amjcard.2008.03.048