Back to Search
Start Over
Identification of factors predictive of lower extremity vein graft thrombosis
- Source :
- Journal of Vascular Surgery. 33:24-31
- Publication Year :
- 2001
- Publisher :
- Elsevier BV, 2001.
-
Abstract
- Objective: The objective of this study was to assess the prognostic value of hemodynamic parameters measured with duplex ultrasound scan, together with other important graft and patient characteristics, in predicting lower extremity vein graft thrombosis. Methods: A total of 165 lower extremity vein grafts were entered prospectively into a postoperative duplex ultrasound scan surveillance program with examinations performed at 1, 2, 3, 4, 6, 9, 12, 18, and 24 months, and annually thereafter. Duplex scan–derived blood flow velocity measurements were recorded at 1562 patient visits over 7 years. Graft patency was determined after each visit, and an analysis of factors predictive of vein graft thrombosis was performed with Poisson regression. Results: Thirty-two episodes of first-time graft thrombosis occurred, 23 of which were permanent. One-, 3-, and 5-year secondary graft patency rates were 90%, 86%, and 79%, respectively. In multivariate analyses, duplex scan velocity measurements predictive of lower extremity graft thrombosis included the maximum velocity ratio (Vr) in association with a graft stenosis and the mean graft peak systolic velocity (MGV) within nonstenotic portions of the body of the graft. The incidence of graft thrombosis among grafts without inflow/outflow stenoses, with Vr less than 3.5, and with MGV 50 cm/s or more, was 2.9% per year. Incidence rates were considerably higher among grafts with a of Vr of 3.5 or more (incidence rate ratio=7.0; 95% CI, 3.4-14.6) or an MGV less than 50 cm/s (incidence rate ratio=6.5; 95% CI, 3.3-13.1). In grafts without identifiable inflow, outflow, or graft stenoses, there was no association between MGV and the risk of graft thrombosis. Conclusion: Duplex scan velocity measurements are valid predictors of impending graft thrombosis. A Vr of 3.5 or more and an MGV less than 50 cm/s are the best predictive measures. Repair of correctable graft lesions with a Vr of 3.5 or more, or inflow, outflow, or graft lesions associated with an MGV less than 50 cm/s are recommended. Grafts without detectable inflow, outflow, or graft stenoses, regardless of MGV, may be safely followed. (J Vasc Surg 2001;33:24-31.)
- Subjects :
- Adult
Male
medicine.medical_specialty
Duplex ultrasonography
Adolescent
Hemodynamics
030204 cardiovascular system & hematology
030230 surgery
Rate ratio
Veins
Blood Vessel Prosthesis Implantation
03 medical and health sciences
0302 clinical medicine
Ischemia
Risk Factors
medicine
Humans
Prospective Studies
Derivation
Prospective cohort study
Aged
Aged, 80 and over
Leg
Ultrasonography, Doppler, Duplex
Vascular disease
business.industry
Graft Occlusion, Vascular
Middle Aged
medicine.disease
Thrombosis
3. Good health
Surgery
surgical procedures, operative
Female
Radiology
Cardiology and Cardiovascular Medicine
business
Complication
Blood Flow Velocity
Subjects
Details
- ISSN :
- 07415214
- Volume :
- 33
- Database :
- OpenAIRE
- Journal :
- Journal of Vascular Surgery
- Accession number :
- edsair.doi.dedup.....9c0cc2c1adc0f128a78087ad3b940dc1