Abstract
- X-ray is a technology that is used for numerous applications in the medical field. The process of X-ray projection gives a 2-dimension (2D) grey-level texture from a 3- dimension (3D) object. Until now no clear demonstration or correlation has positioned the 2D texture analysis as a valid indirect evaluation of the 3D microarchitecture. TBS is a new texture parameter based on the measure of the experimental variogram. TBS evaluates the variation between 2D image grey-levels. The aim of this study was to evaluate existing correlations between 3D bone microarchitecture parameters - evaluated from μCT reconstructions - and the TBS value, calculated on 2D projected images. 30 dried human cadaveric vertebrae were acquired on a micro-scanner (eXplorer Locus, GE) at isotropic resolution of 93 μm. 3D vertebral body models were used. The following 3D microarchitecture parameters were used: Bone volume fraction (BV/TV), Trabecular thickness (TbTh), trabecular space (TbSp), trabecular number (TbN) and connectivity density (ConnD). 3D/2D projections has been done by taking into account the Beer-Lambert Law at X-ray energy of 50, 100, 150 KeV. TBS was assessed on 2D projected images. Correlations between TBS and the 3D microarchitecture parameters were evaluated using a linear regression analysis. Paired T-test is used to assess the X-ray energy effects on TBS. Multiple linear regressions (backward) were used to evaluate relationships between TBS and 3D microarchitecture parameters using a bootstrap process. BV/TV of the sample ranged from 18.5 to 37.6% with an average value at 28.8%. Correlations' analysis showedthat TBSwere strongly correlatedwith ConnD(0.856≤r≤0.862; p
- Subjects :
- Histology
business.industry
Physiology
Endocrinology, Diabetes and Metabolism
Microarchitecture
Correlation
Bone volume fraction
Trabecular bone score
Linear regression
Medicine
Radiology, Nuclear Medicine and imaging
Orthopedics and Sports Medicine
Texture (crystalline)
business
Isotropic resolution
Variogram
Mathematics
Biomedical engineering
Subjects
Details
- ISSN :
- 87563282
- Volume :
- 48
- Database :
- OpenAIRE
- Journal :
- Bone
- Accession number :
- edsair.doi.dedup.....9f7f8258f96fb6717383ad9be8f57666
- Full Text :
- https://doi.org/10.1016/j.bone.2011.03.404