Back to Search Start Over

Digital Quantification Method for Sensitive Point-of-Care Detection of Salivary Uric Acid Using Smartphone-Assisted μPADs

Authors :
Kexin Fan
Jiayang Zeng
Chenyu Yang
Gonglei Wang
Kai Lian
Xiuhong Zhou
Yaping Deng
Guozhen Liu
Source :
ACS Sensors. 7:2049-2057
Publication Year :
2022
Publisher :
American Chemical Society (ACS), 2022.

Abstract

Uric acid (UA) is an important biomarker for many diseases. A sensitive point-of-care (POC) testing platform is designed for the digital quantification of salivary UA based on a colorimetric reaction on an easy-to-build smartphone-assisted microfluidic paper-based analytical device (SμPAD). UA levels are quantified according to the color intensity of Prussian blue on the SμPAD with the aid of a MATLAB code or a smartphone APP. A color correction method is specifically applied to exclude the light effect. Together with the engineering design of SμPADs, the background calibration function with the APP increases the UA sensitivity by 100-fold to reach 0.1 ppm with a linear range of 0.1-200 ppm. The assay time is less than 10 min. SμPADs demonstrate a correlation of 0.97 with a commercial UA kit for the detection of salivary UA in clinical samples. SμPADs provide a sensitive, fast, affordable, and reliable tool for the noninvasive POC quantification of salivary UA for early diagnosis of abnormal UA level-associated health conditions.

Details

ISSN :
23793694
Volume :
7
Database :
OpenAIRE
Journal :
ACS Sensors
Accession number :
edsair.doi.dedup.....a02a982c35767e7ff2069a62e2b800df
Full Text :
https://doi.org/10.1021/acssensors.2c00854