Back to Search Start Over

Feasibility and safety of laser balloon pulmonary vein isolation in patients with prior left atrial appendage occlusion device implantation

Authors :
Charl Khalil
Sharath C. Vipparthy
David Kenigsberg
Venkatesh Ravi
Sorin Lazar
Rami Doukky
Grzegorz Pietrasik
Jeremiah Wasserlauf
Timothy Larsen
Parikshit S. Sharma
Henry D. Huang
Source :
Journal of cardiovascular electrophysiologyREFERENCES. 33(11)
Publication Year :
2022

Abstract

With the increasing adoption of left atrial appendage occlusion (LAAO) procedures and the eligibility of patients for pulmonary vein isolation (PVI) post device placement, we examined the feasibility and safety of laser balloon (LB) for PVI in patients with prior LAAO.We retrospectively examined consecutive patients with paroxysmal or persistent, drug-resistant atrial fibrillation (AF) who underwent LB PVI, after Watchman FLX device implantation at Rush University Medical Center between January 2020 and December 2021.Seven patients (four persistent and three paroxysmal) with a mean age of 64 ± 11 years, predominantly male sex (86%), were included in the study. Two (29%) patients had prior cryoablation PVI with recurrence of AF. The mean CHALB PVI was safe and effective with 100% acute isolation of left-sided veins in patients with prior LAAO device.