Back to Search Start Over

Quantitative Visualization of Thermally Enhanced Perpendicular Shape Anisotropy STT-MRAM Nanopillars

Authors :
Trevor P. Almeida
Steven Lequeux
Alvaro Palomino
Ricardo C. Sousa
Olivier Fruchart
Ioan-Lucian Prejbeanu
Bernard Dieny
Aurélien Masseboeuf
David Cooper
Commissariat à l'énergie atomique et aux énergies alternatives - Laboratoire d'Electronique et de Technologie de l'Information (CEA-LETI)
Direction de Recherche Technologique (CEA) (DRT (CEA))
Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Commissariat à l'énergie atomique et aux énergies alternatives (CEA)
SPINtronique et TEchnologie des Composants (SPINTEC)
Centre National de la Recherche Scientifique (CNRS)-Institut de Recherche Interdisciplinaire de Grenoble (IRIG)
Direction de Recherche Fondamentale (CEA) (DRF (CEA))
Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Direction de Recherche Fondamentale (CEA) (DRF (CEA))
Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Université Grenoble Alpes (UGA)
European Project: 669204,H2020,ERC-2014-ADG,MAGICAL(2015)
Source :
Nano Letters, Nano Letters, 2022, 22 (10), pp.4000. ⟨10.1021/acs.nanolett.2c00597⟩
Publication Year :
2022
Publisher :
American Chemical Society (ACS), 2022.

Abstract

International audience; Perpendicular shape anisotropy (PSA) offers a practical solution to downscale spin-transfer torque magnetoresistive random-access memory (STT-MRAM) beyond the sub-20 nm technology node while retaining thermal stability. However, our understanding of the thermomagnetic behavior of PSA-STT-MRAM is often indirect, relying on magnetoresistance measurements and micromagnetic modeling. Here, the magnetism of a NiFe PSA-STT-MRAM nanopillar is investigated using off-axis electron holography, providing spatially resolved magnetic information as a function of temperature. Magnetic induction maps reveal the micromagnetic configuration of the NiFe storage layer (∼60 nm high, ≤20 nm diameter), confirming the PSA induced by its 3:1 aspect ratio. In situ heating demonstrates that the PSA of the storage layer is maintained up to at least 250 °C, and direct quantitative measurements reveal a moderate decrease of magnetic induction. Hence, this study shows explicitly that PSA provides significant stability in STT-MRAM applications that require reliable performance over a range of operating temperatures.

Details

ISSN :
15306992 and 15306984
Volume :
22
Database :
OpenAIRE
Journal :
Nano Letters
Accession number :
edsair.doi.dedup.....a24a597baf18e2a82ced52367d8caf47
Full Text :
https://doi.org/10.1021/acs.nanolett.2c00597