Back to Search
Start Over
Fones de inserção: aplicação no colabamento de meato acústico externo
- Source :
- Revista da Sociedade Brasileira de Fonoaudiologia v.17 n.1 2012, Revista da Sociedade Brasileira de Fonoaudiologia, Sociedade Brasileira de Fonoaudiologia (SBF), instacron:SBF, Revista da Sociedade Brasileira de Fonoaudiologia, Volume: 17, Issue: 1, Pages: 61-65, Published: MAR 2012
- Publication Year :
- 2012
- Publisher :
- Sociedade Brasileira de Fonoaudiologia, 2012.
-
Abstract
- OBJETIVO: Determinar a eficácia dos fones de inserção em casos de suspeita de colabamento de meato acústico externo. MÉTODOS: Vinte e um idosos com intervalo aéreo-ósseo superior a 10 dBNA nas frequências de 3 kHz e/ou 4 kHz foram submetidos à anamne se, audiometria tonal liminar, logoaudiometria e imitanciometria. A audiometria tonal e a logoaudiometria foram realizadas com os fones supra-aurais e com fones de inserção. RESULTADOS: Verificou-se que os limiares auditivos por via aérea obtidos com os fones de inserção foram menores em todas as frequências com exceção de 1 kHz. O intervalo aéreo-ósseo também foi menor com o fone de inserção, havendo um acoplamento aéreo-ósseo com este transdutor. CONCLUSÃO: Os fones de inserção ER-3A possibilitam melhora significativa nos limiares de audibilidade por via aérea em idosos, diminuindo ou até eliminando o intervalo aéreo-ósseo, sobretudo nas frequências altas, nos casos de colabamento do meato acústico externo. PURPOSE: To determine the efficacy of insert earphones in cases of collapsed external auditory canals. METHODS: Twenty-one elderly individuals with air-bone gaps greater than 10 dBHL at frequencies of 3 kHz and/or 4 kHz underwent anamnesis, pure tone audiometry, speech audiometry, and immittance test. Pure tone audiometry and speech audiometry were performed with both supra-aural and insert earphones. RESULTS: Air conduction thresholds were lower with insert earphones at all frequencies except 1 kHz. The magnitude of the air-bone gap was also lower with the insert earphones, and there was a air-bone coupling with this transducer. CONCLUSION: Insert earphones ER-3A allowed significant improvement in air conduction hearing thresholds in elderly individuals, reducing or even eliminating the air-bone gap in cases of collapsed external auditory canals, especially at higher frequencies.
Details
- Language :
- Portuguese
- Database :
- OpenAIRE
- Journal :
- Revista da Sociedade Brasileira de Fonoaudiologia v.17 n.1 2012, Revista da Sociedade Brasileira de Fonoaudiologia, Sociedade Brasileira de Fonoaudiologia (SBF), instacron:SBF, Revista da Sociedade Brasileira de Fonoaudiologia, Volume: 17, Issue: 1, Pages: 61-65, Published: MAR 2012
- Accession number :
- edsair.doi.dedup.....a2ecf7b2589f4f9f634724f0f8bd0ebb