Back to Search
Start Over
The Olympia anatomic polished cemented stem is associated with a high survivorship, excellent hip-specific functional outcome, and high satisfaction levels: follow-up of 239 consecutive patients beyond 15 years
- Source :
- Turnbull, G S, Marshall, C, Nicholson, J A, MacDonald, D J, Clement, N D & Breusch, S J 2022, ' The Olympia anatomic polished cemented stem is associated with a high survivorship, excellent hip-specific functional outcome, and high satisfaction levels : follow-up of 239 consecutive patients beyond 15 years ', Archives of Orthopaedic and Trauma Surgery, vol. 142, pp. 2361–2370 . https://doi.org/10.1007/s00402-021-03992-z
- Publication Year :
- 2021
- Publisher :
- Springer Science and Business Media LLC, 2021.
-
Abstract
- Introduction The Olympia femoral stem is a stainless steel, anatomically shaped, polished and three-dimensionally tapered implant designed for use in cemented total hip arthroplasty (THA). The primary aim of this study was to determine the long-term survivorship, radiographic outcome, and patient-reported outcome measures (PROMs) of the Olympia stem. Patients and methods Between May 2003 and December 2005, 239 patients (264 THAs) underwent a THA with an Olympia stem in our institution. Patient-reported outcome measures were assessed using the Oxford Hip Score (OHS), EuroQol-5 dimensions (EQ-5D) score, and patient satisfaction at mean 10 years following THA. Patient records and radiographs were then reviewed at a mean of 16.5 years (SD 0.7, 15.3–17.8) following THA to identify occurrence of complications or revision surgery for any cause following surgery. Radiographs were assessed for lucent lines and lysis according to Gruen’s zones Results Mean patient age at surgery was 68.0 years (SD 10.9, 31–93 years). There were 156 women (65%, 176 THAs). Osteoarthritis was the indication for THA in 204 patients (85%). All cause stem survivorship at 10 years was 99.2% (95% confidence interval [CI], 97.9%–100%) and at 15 years was 97.5% (94.6%–100%). The 15-year stem survival for aseptic loosening was 100%. Analysis of all-cause THA failure demonstrated a survivorship of 98.5% (96.3%–100%) at 10 years and 95.9% (92.4%–99.4%) at 15 years. There were 9 THAs with non-progressive lucent lines in a single Gruen zone and 3 had lines in two zones, and no patient demonstrated signs for lysis. At a mean of 10-year (SD 0.8, 8.7–11.3) follow-up, mean OHS was 39 (SD 10.3, range 7–48) and 94% of patients reported being very satisfied or satisfied with their THA. Conclusions The Olympia stem demonstrated excellent 10-year PROMs and very high rates of stem survivorship at final follow-up beyond 15 years.
- Subjects :
- THA
cement
Reoperation
musculoskeletal diseases
medicine.medical_specialty
Arthroplasty, Replacement, Hip
Radiography
Personal Satisfaction
Survivorship
Osteoarthritis
Oxford hip score
Prosthesis Design
PROMs
03 medical and health sciences
0302 clinical medicine
Patient satisfaction
TA164
Survivorship curve
medicine
Humans
Orthopedics and Sports Medicine
stem
030212 general & internal medicine
Retrospective Studies
030222 orthopedics
business.industry
polished
General Medicine
anatomic
medicine.disease
Confidence interval
Prosthesis Failure
Surgery
Treatment Outcome
Patient Satisfaction
Orthopedic surgery
Gold Alloys
Female
Hip Prosthesis
Implant
business
survivorship
Follow-Up Studies
Subjects
Details
- ISSN :
- 14343916
- Volume :
- 142
- Database :
- OpenAIRE
- Journal :
- Archives of Orthopaedic and Trauma Surgery
- Accession number :
- edsair.doi.dedup.....a3e73c4b2a5c34425a1a6c9bf820ea46
- Full Text :
- https://doi.org/10.1007/s00402-021-03992-z