Back to Search Start Over

Clinical utility of late-night and post-overnight dexamethasone suppression salivary cortisone for the investigation of Cushing's syndrome

Authors :
C M Ng
T K Lam
Y C Au Yeung
C C Shek
Y P Iu
S C Tiu
C H Choi
Source :
Hong Kong medical journal = Xianggang yi xue za zhi. 23(6)
Publication Year :
2017

Abstract

Introduction There is a pressing need to identify diagnostic testing for Cushing's syndrome that can be achieved with ease and at low cost. This study aimed to explore the usefulness of late-night and post-overnight 1-mg dexamethasone suppression salivary cortisone, as measured by liquid chromatography-tandem mass spectrometry, for investigation of hypercortisolism. Methods Salivary cortisone data of subjects were investigated according to a pre-specified protocol. Subjects were classified as having 'hypercortisolism' or 'eucortisolism' on the basis of histological or biochemical criteria. Receiver operating characteristic curves were drawn to identify the cut-off values and study their performance characteristics. We measured 24-hour urinary free cortisol; late-night salivary cortisol and cortisone; and post-overnight 1-mg dexamethasone suppression serum cortisol, and salivary cortisol and cortisone. Saliva and urine samples were assayed by liquid chromatography-tandem mass spectrometry. Results In this study, 21 subjects were classified as having hypercortisolism and 78 as having eucortisolism. A late-night salivary cortisone cut-off of 13.50 nmol/L had a sensitivity of 94.7% and a specificity of 87.2%. After taking 1-mg dexamethasone the night before, a salivary cortisol cut-off of 0.85 nmol/L had a sensitivity of 76.2% and a specificity of 96.2%; a salivary cortisone cut-off of 7.45 nmol/L had a sensitivity of 85.7% and a specificity of 94.9%, while a salivary cortisone cut-off of 3.25 nmol/L had a sensitivity of 95.2% and a specificity of 79.5%. Many salivary cortisol samples were below the detection limit of liquid chromatography-tandem mass spectrometry. In comparison with salivary cortisol, salivary cortisone had a better correlation with total serum cortisol and better diagnostic performance following dexamethasone suppression. Conclusions Both late-night and post-overnight dexamethasone suppression salivary cortisone levels are of diagnostic value in the investigation of hypercortisolism.

Details

ISSN :
10242708
Volume :
23
Issue :
6
Database :
OpenAIRE
Journal :
Hong Kong medical journal = Xianggang yi xue za zhi
Accession number :
edsair.doi.dedup.....a5a3ceb6f65416d935ce39295b3996a2