Test of long scintillation counters for supercollider detectors
- Source :
- Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 343:484-488
- Publication Year :
- 1994
- Publisher :
- Elsevier BV, 1994.
-
Abstract
- A number of long scintillator counters employing UPS 923A and NE 114 plastic scintillators seen by a single photomultiplier were tested using cosmic muons. These counters have suitable dimensions to be used in large arrays in a proton supercollider experiment. The efficiency for m.i.p. was excellent in all cases. The yield of UPS 923A was found to be by about 25% higher than NE 114, while the attenuation length was approximately the same.