Iodine Parameters in Triple-Bolus Dual-Energy CT Correlate With Perfusion CT Biomarkers of Angiogenesis in Renal Cell Carcinoma

Authors :
Manoharan D
Sanjay Sharma
Arjunlokesh Netaji
Chandan J Das
Source :
American Journal of Roentgenology. 214:808-816
Publication Year :
2020
Publisher :
American Roentgen Ray Society, 2020.

Abstract

OBJECTIVE. The purpose of this study is to determine the degree of the relationship between perfusion CT (PCT) parameters and iodine concentration metrics derived from triple-bolus dual-energy CT (DECT) and to compare the radiation dose delivered. SUBJECTS AND METHODS. This single-center prospective study was conducted from October 2015 to September 2017. Twenty-three consenting adults (15 men and eight women; mean [± SD] age, 56 ± 13 years [range, 25-78 years]) with renal cell carcinomas underwent consecutive PCT and triple-bolus DECT examinations. Triple-bolus DECT consisted of synchronous corticomedullary, nephrographic, and delayed phase scans acquired using a dual-source DECT scanner. Two readers independently analyzed blood flow, blood volume, and permeability, as measured by PCT, and iodine density and iodine ratio, as measured by triple-bolus DECT. Size-specific dose estimates were calculated for both groups. RESULTS. Interreader agreement was good for permeability (intraclass correlation coefficient [ICC] =.812) and blood flow (ICC = 0.849) and excellent for blood volume (ICC = 0.956), iodine density (ICC = 0.961), and iodine ratio (ICC = 0.956). Very strong positive correlations were found between blood volume and iodine density (p < 0.001) and between blood volume and iodine ratio (p < 0.001). Strong positive correlations were found between blood flow and iodine density (p < 0.001) and between blood flow and iodine ratio (p < 0.001). The correlations between permeability and iodine density (p = 0.01) and between permeability and iodine ratio (p = 0.02) were moderate. The mean size-specific dose estimate of triple-bolus DECT was approximately 15 times lower than that of PCT (p < 0.001). CONCLUSION. Quantitative iodine metrics derived from triple-bolus DECT showed significant correlation with CT parameters in renal cell carcinoma, with a significantly lower radiation dose.

Details

ISSN :
15463141 and 0361803X
Volume :
214
Database :
OpenAIRE
Journal :
American Journal of Roentgenology
Accession number :
edsair.doi.dedup.....ad1ad4d48829bec2b1216003981db665
Full Text :
https://doi.org/10.2214/ajr.19.21969