Back to Search
Start Over
Diagnostic Accuracy of 320-Row Computed Tomography for Characterizing Coronary Atherosclerotic Plaques: Comparison with Intravascular Optical Coherence Tomography
- Source :
- Cardiovascular Revascularization Medicine. 21:640-646
- Publication Year :
- 2020
- Publisher :
- Elsevier BV, 2020.
-
Abstract
- This study sought to determine the diagnostic accuracy of 320-row computed tomography (320CT) for characterizing coronary atherosclerotic plaques in comparison with optical coherence tomography (OCT).From 32 patients, 42 coronary segments were evaluated and co-registered by both 320CT and OCT. 320CT vulnerable plaque characteristics included low attenuation plaque (LAP) (30HU), napkin-ring sign (NRS), positive remodeling (PR) and spotty calcification (SC). The presence of macrophage, neovascularization and cholesterol crystals was also determined by OCT.Minimal lumen area was 2.78 ± 1.23 mm by OCT and 3.29 ± 1.49 mm by 320CT (p 0.001). Noncalcified plaques were classified accordingly by both methods in 88.2% of the cases (p = 0.005). There was no association between any 320CT plaque type and OCT fibroatheroma (p = 0.62). The combination of 2 or more of the 320CT vulnerable plaque characteristics was associated with the presence of macrophage (74.2 vs. 25.8%; p = 0.034) and cholesterol crystals (85.7 vs. 14.3%; p = 0.04), but not with neovascularization (p = 0.65). The presence of all four characteristics demonstrated an accuracy of 75.1% for detecting OCT fibroatheroma.320CT is useful for non-invasive evaluation of calcified and noncalcified tissue characteristics of coronary atheroma. The combination of all four 320CT vulnerable plaque characteristics provided the highest accuracy for detecting fibroatheromas.320CT is useful for non-invasive evaluation of calcified and noncalcified tissue characteristics of coronary atheroma. The combination of all 320CT vulnerable plaque characteristics (low attenuation plaque (30HU), napkin-ring sign, positive remodeling and spotty calcification) provided the highest accuracy for detecting fibroatheromas compared to optical coherence tomography.
- Subjects :
- Male
medicine.medical_specialty
Computed Tomography Angiography
Lumen (anatomy)
Diagnostic accuracy
Computed tomography
Coronary Artery Disease
030204 cardiovascular system & hematology
Coronary Angiography
medicine.disease_cause
Coronary artery disease
03 medical and health sciences
0302 clinical medicine
Optical coherence tomography
Predictive Value of Tests
Multidetector Computed Tomography
medicine
Humans
Registries
030212 general & internal medicine
Vascular Calcification
Aged
Retrospective Studies
Neovascularization, Pathologic
medicine.diagnostic_test
business.industry
Macrophages
Reproducibility of Results
General Medicine
Tissue characterization
Middle Aged
Prognosis
medicine.disease
Coronary Vessels
Fibrosis
Vulnerable plaque
Plaque, Atherosclerotic
Cholesterol
CORONARY ATHEROMA
Female
Radiology
Crystallization
Cardiology and Cardiovascular Medicine
business
Tomography, Optical Coherence
Subjects
Details
- ISSN :
- 15538389
- Volume :
- 21
- Database :
- OpenAIRE
- Journal :
- Cardiovascular Revascularization Medicine
- Accession number :
- edsair.doi.dedup.....adf6cf0aab432f87a201dc9fc1986fbf
- Full Text :
- https://doi.org/10.1016/j.carrev.2019.08.010