Back to Search Start Over

Evaluation in pig of an intestinal administration device for oral peptide delivery

Authors :
Staffan Berg
Teresia Uggla
Malin Antonsson
Sandro Filipe Nunes
Maria Englund
Louise Rosengren
Masoud Fahraj
Xiaoqiu Wu
Rydvikha Govender
Magnus Söderberg
David Janzén
Natalie Van Zuydam
Andreas Hugerth
Anette Larsson
Susanna Abrahmsén-Alami
Bertil Abrahamsson
Nigel Davies
Christel A.S. Bergström
Source :
Journal of Controlled Release. 353:792-801
Publication Year :
2023
Publisher :
Elsevier BV, 2023.

Abstract

The bioavailability of peptides co-delivered with permeation enhancers following oral administration remains low and highly variable. Two factors that may contribute to this are the dilution of the permeation enhancer in the intestinal fluid, as well as spreading of the released permeation enhancer and peptide in the lumen by intestinal motility. In this work we evaluated an Intestinal Administration Device (IAD) designed to reduce the luminal dilution of drug and permeation enhancer, and to minimize movement of the dosage form in the intestinal lumen. To achieve this, the IAD utilizes an expanding design that holds immediate release mini tablets and places these in contact with the intestinal epithelium, where unidirectional drug release can occur. The expanding conformation limits movement of the IAD in the intestinal tract, thereby enabling drug release at a single focal point in the intestine. A pig model was selected to study the ability of the IAD to promote intestinal absorption of the peptide MEDI7219 formulated together with the permeation enhancer sodium caprate. We compared the IAD to intestinally administered enteric coated capsules and an intestinally administered solution. The IAD restricted movement of the immediate release tablets in the small intestine and histological evaluation of the mucosa indicated that high concentrations of sodium caprate were achieved. Despite significant effect of the permeation enhancer on the integrity of the intestinal epithelium, the bioavailability of MEDI7219 was of the same order of magnitude as that achieved with the solution and enteric coated capsule formulations (2.5-3.8%). The variability in plasma concentrations of MEDI7219 were however lower when delivered using the IAD as compared to the solution and enteric coated capsule formulations. This suggests that dosage forms that can limit intestinal dilution and control the position of drug release can be a way to reduce the absorptive variability of peptides delivered with permeation enhancers but do not offer significant benefits in terms of increasing bioavailability.

Subjects

Subjects :
Pharmaceutical Science

Details

ISSN :
01683659
Volume :
353
Database :
OpenAIRE
Journal :
Journal of Controlled Release
Accession number :
edsair.doi.dedup.....ae5216cabbeef7261032d70af99ef3d2