Back to Search
Start Over
Bayesian Machine Learning Classifiers for Combining Structural and Functional Measurements to Classify Healthy and Glaucomatous Eyes
- Source :
- Investigative Opthalmology & Visual Science. 49:945
- Publication Year :
- 2008
- Publisher :
- Association for Research in Vision and Ophthalmology (ARVO), 2008.
-
Abstract
- PURPOSE.To determine whether combining structural (optical coherence tomography, OCT) and functional (standard automated perimetry, SAP) measurements as input for machine learning classifiers (MLCs; relevance vector machine, RVM; and subspace mixture of Gaussians, SSMoG) improves diagnostic accuracy for detecting glaucomatous eyes compared with using each measurement method alone. METHODS.Sixty-nine eyes of 69 healthy control subjects (average age, 62.0, SD 9.7 years; visual field mean deviation [MD], !0.70, SD 1.41 dB) and 156 eyes of 156 patients with glaucoma (average age, 66.4, SD 10.2 years; visual field MD,!3.12, SD 3.43 dB) were imaged with OCT (Stratus OCT, Carl Zeiss Meditec, Inc., Dublin, CA) and tested with SAP (Humphrey Field Analyzer II with Swedish Interactive Thresholding Algorithm, SITA; Carl Zeiss Meditec, Inc.) within 3 months of each other. RVM and SSMoG MLCs were trained and tested on OCT-determined RNFL thickness measurements from 32 sectors ("11.25° each) obtained in the circumpapillary area under the instrument-defined measurement ellipse and SAP pattern deviation values from 52 points from the 24-2 grid, independently and in combination. Tenfold cross-validation was used to train and test classifiers on unique subsets of the full 225-eye data set, and areas under the receiver operating characteristic curve (AUROC) for the classification of eyes in the test set were generated. AUROC results from classifiers trained on OCT and SAP alone and those trained on OCT and SAP in combination were compared. In addition, these results were compared to currently available OCT measurements (mean retinal nerve fiber layer [RNFL] thickness, inferior RNFL thickness, and superior RNFL thickness) and SAP indices (MD and pattern standard deviation [PSD]). RESULTS.The AUROCs for RVM trained on OCT parameters alone, SAP parameters alone and OCT and SAP parameters combined were 0.809, 0.815, and 0.845, respectively. The AUROCs for SSMoG trained on OCT parameters alone, SAP parameters alone, and OCT and SAP parameters combined were 0.817, 0.841, and 0.869, respectively. Combining techniques using both RVM and SSMoG significantly improved on MLC analysis of OCT, but not SAP, measurements alone. Classification performance using RVM and SSMoG was statistically similar. C ONCLUSIONS.RVM and SSMoG Bayesian MLCs trained on OCT and SAP data can successfully discriminate between healthy and early glaucomatous eyes. Combining OCT and SAP measurements using RVM and SSMoG increased diagnostic performance marginally compared with MLC analysis of data obtained using each technology alone. (Invest Ophthalmol Vis Sci.2008;49:945‐953) DOI:10.1167/iovs.07-1083
- Subjects :
- Adult
Retinal Ganglion Cells
genetic structures
Optic Disk
Bayesian probability
Vision Disorders
Glaucoma
Machine learning
computer.software_genre
Relevance vector machine
Tonometry, Ocular
Nerve Fibers
Optical coherence tomography
Optic Nerve Diseases
medicine
Humans
Aged
Mathematics
Aged, 80 and over
medicine.diagnostic_test
Receiver operating characteristic
business.industry
Bayes Theorem
Middle Aged
medicine.disease
eye diseases
Visual field
Data set
Cross-Sectional Studies
ROC Curve
Visual Field Tests
sense organs
Artificial intelligence
Visual Fields
business
computer
Algorithms
Glaucoma, Open-Angle
Tomography, Optical Coherence
Swedish interactive thresholding algorithm
Subjects
Details
- ISSN :
- 15525783
- Volume :
- 49
- Database :
- OpenAIRE
- Journal :
- Investigative Opthalmology & Visual Science
- Accession number :
- edsair.doi.dedup.....b0082b29a52eee74b7771a715f53bcb0
- Full Text :
- https://doi.org/10.1167/iovs.07-1083