Back to Search
Start Over
Gadoxetic acid-enhanced dynamic magnetic resonance imaging using optimized integrated combination of compressed sensing and parallel imaging technique
- Source :
- Magnetic Resonance Imaging. 57:111-117
- Publication Year :
- 2019
- Publisher :
- Elsevier BV, 2019.
-
Abstract
- To evaluate the feasibility of optimized integrated combination of compressed sensing and parallel imaging technique (prototype Compressed SENSE) in gadoxetic acid-enhanced dynamic magnetic resonance (MR) imaging.Sixty-one patients underwent gadoxetic acid-enhanced dynamic imaging using enhanced T1 high-resolution isotropic volume excitation (eTHRIVE) with the Compressed SENSE (CS-eTHRIVE; C SENSE factor, 3.4; acquisition time, 10 s). Results were compared with 61 propensity score-matched patients who underwent conventional eTHRIVE (eTHRIVE; acquisition time, 20 s). For quantitative image analyses, signal intensity ratio (SIR) and signal-to-noise ratio (SNR), coefficient of variation (CV) of liver parenchyma were calculated in each dynamic phase. For qualitative image analyses, two radiologists rated the homogeneity of liver parenchyma, sharpness of liver edge and left external lobe, motion artifacts, and overall image quality in each dynamic phase using a five-point scale.SIRs of liver parenchyma with CS-eTHRIVE were significantly higher than with eTHRIVE in the hepatic arterial phase (HAP) (1.70 vs. 1.52) and transitional phase (TP) (2.18 vs. 2.06) (P ≤ 0.030). SNR of liver parenchyma were comparable between the two sequences in all phases. CV of liver parenchyma in HAP with eTHRIVE (0.079) was significantly higher than with CS-eTHRIVE (0.065) (P 0.001). Motion artifacts were significantly reduced with CS-eTHRIVE compared with eTHRIVE in all phases (P ≤ 0.005). The appearance ratio of extensive motion artifacts in HAP with CS-eTHRIVE (0/61; 0%) were significantly reduced compared with eTHRIVE (4/61; 6.6%) (P = 0.042). Overall image quality with CS-eTHRIVE was significantly better than with eTHRIVE in all phases (P ≤ 0.039).CS-eTHRIVE compared with eTHRIVE effectively reduced the acquisition time and extensive motion artifacts without degradation of image quality.
- Subjects :
- Adult
Gadolinium DTPA
Male
Gadoxetic acid
Materials science
Image quality
Dynamic imaging
Coefficient of variation
Biomedical Engineering
Biophysics
Contrast Media
Signal-To-Noise Ratio
030218 nuclear medicine & medical imaging
Motion
03 medical and health sciences
Hepatic Artery
0302 clinical medicine
medicine
Humans
Radiology, Nuclear Medicine and imaging
Prospective Studies
Aged
Aged, 80 and over
medicine.diagnostic_test
Magnetic resonance imaging
Middle Aged
Data Compression
Image Enhancement
Magnetic Resonance Imaging
Compressed sensing
Liver
Female
Parallel imaging
Artifacts
030217 neurology & neurosurgery
Arterial phase
Biomedical engineering
medicine.drug
Subjects
Details
- ISSN :
- 0730725X
- Volume :
- 57
- Database :
- OpenAIRE
- Journal :
- Magnetic Resonance Imaging
- Accession number :
- edsair.doi.dedup.....b44db46f4bcb91f856905f6c68706835