Assessing cardiac preload by the Initial Systolic Time Interval obtained from impedance cardiography
- Source :
- Journal of Electrical Bioimpedance, 1(1), 80-83. Oslo Bioimpedance Group, Department of Physics, University of Oslo, Meijer, J H, Smorenberg, A, Lust, E J, Verdaasdonk, R M & Groeneveld, A B J 2020, ' Assessing cardiac preload by the Initial Systolic Time Interval obtained from impedance cardiography ', Journal of Electrical Bioimpedance, vol. 1, no. 1, pp. 80-83 . https://doi.org/10.5617/jeb.141, Journal of Electrical Bioimpedance, Vol 1, Iss 1, Pp 80-83 (2010)
- Publication Year :
- 2020
-
Abstract
- The Initial Systolic Time Interval (ISTI), obtained from the electrocardiogram (ECG) and impedance cardiogram (ICG), is considered to be a measure for the time delay between the electrical and mechanical activity of the heart and reflects an early active period of the cardiac cycle. The clinical relevance of this time interval is subject of study. This paper introduces a method using ISTI to evaluate and predict the circulatory response to fluid administration in patients after coronary artery bypass graft surgery and presents preliminary results of a pilot study by comparing ISTI with cardiac output (CO) responsiveness. Also the use of the pulse transit time (PTT), earlier recommended for this purpose, was investigated. The results showed an inverse relationship between ISTI and CO at all moments of fluid administration and also an inverse relationship between the changes ΔISTI and ΔCO before and after full fluid administration. No relationships between PTT and CO or ΔPTT and ΔCO were found. It is concluded that ISTI is dependent upon preload, and that ISTI has the potential to be used as a clinical parameter assessing preload.
- Subjects :
- Fluid administration
medicine.medical_specialty
Cardiac output
Multifunction cardiogram
Biomedical Engineering
Biophysics
coronary artery bypass graft surgery
Internal medicine
medicine
impedance cardiography
lcsh:R5-920
medicine.diagnostic_test
Cardiac cycle
Bioimpedance
business.industry
cardiac preload
Impedance cardiography
Preload
medicine.anatomical_structure
Systolic time intervals
initial systolic time interval
Anesthesia
Cardiology
business
lcsh:Medicine (General)
Artery
Subjects
Details
- Language :
- English
- ISSN :
- 18915469
- Database :
- OpenAIRE
- Journal :
- Journal of Electrical Bioimpedance, 1(1), 80-83. Oslo Bioimpedance Group, Department of Physics, University of Oslo, Meijer, J H, Smorenberg, A, Lust, E J, Verdaasdonk, R M & Groeneveld, A B J 2020, ' Assessing cardiac preload by the Initial Systolic Time Interval obtained from impedance cardiography ', Journal of Electrical Bioimpedance, vol. 1, no. 1, pp. 80-83 . https://doi.org/10.5617/jeb.141, Journal of Electrical Bioimpedance, Vol 1, Iss 1, Pp 80-83 (2010)
- Accession number :
- edsair.doi.dedup.....b582a6dff513c28000901344246b62a8
- Full Text :
- https://doi.org/10.5617/jeb.141