Back to Search Start Over

Signal yields, energy resolution, and recombination fluctuations in liquid xenon

Authors :
Henrique Araujo
Jilei Xu
C. Nehrkorn
Matthew Szydagis
B. G. Lenardo
T. J. Sumner
C. R. Hall
M. C. Carmona-Benitez
M. Solmaz
K. Kamdin
Sidney Cahn
P. Beltrame
Mani Tripathi
K.R. Gibson
R.G. Jacobsen
D. Byram
S. Stephenson
M. F. Marzioni
A. Lindote
L. Reichhart
Witherell
R. C. Webb
K. O'Sullivan
Sarah Young
P. A. Terman
C. M. Ignarra
F.L.H. Wolfs
T. A. Shutt
N.A. Larsen
D. Q. Huang
J. A. Morad
Tiedt
Daniel McKinsey
J. E. Y. Dobson
S. J. Haselschwardt
S. Shaw
P. Brás
R. Bramante
P. Phelps
K. Kazkaz
A.A. Chiller
C. Chiller
B. P. Tennyson
D. Khaitan
M.I. Lopes
R. Knoche
C. H. Faham
K. J. Palladino
E. M. Boulton
M. Hanhardt
C. Ghag
E. K. Pease
C. Silva
D. M. Mei
V. N. Solovov
T. J. R. Davison
K. C. Oliver-Mallory
M. G. D. Gilchriese
A. Bernstein
S. Alsum
A. Dobi
A. Manalaysay
A. J. Bailey
B. N. Edwards
H. N. Nelson
L. Tvrznikova
M. Moongweluwan
D. P. Hogan
X. Bai
P. Sorensen
Ethan Bernard
M. Horn
R. L. Mannino
V. M. Gehman
F. Neves
J. Mock
Verbus
S. A. Hertel
E. Druszkiewicz
A. Currie
T. P. Biesiadzinski
M. Ihm
S. Uvarov
K. Yazdani
Chao Zhang
K. T. Lesko
C. Lee
C. Chan
W. Ji
T. J. Whitis
J. T. White
C. Rhyne
D. J. Taylor
R. J. Gaitskell
D. S. Akerib
A. Murphy
J. E. Cutter
W. C. Taylor
J. Balajthy
W. H. To
S. Fiorucci
Source :
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos), Agência para a Sociedade do Conhecimento (UMIC)-FCT-Sociedade da Informação, instacron:RCAAP, BASE-Bielefeld Academic Search Engine
Publication Year :
2017
Publisher :
American Physical Society, 2017.

Abstract

This work presents an analysis of monoenergetic electronic recoil peaks in the dark-matter-search and calibration data from the first underground science run of the Large Underground Xenon (LUX) detector. Liquid xenon charge and light yields for electronic recoil energies between 5.2 and 661.7 keV are measured, as well as the energy resolution for the LUX detector at those same energies. Additionally, there is an interpretation of existing measurements and descriptions of electron-ion recombination fluctuations in liquid xenon as limiting cases of a more general liquid xenon re- combination fluctuation model. Measurements of the standard deviation of these fluctuations at monoenergetic electronic recoil peaks exhibit a linear dependence on the number of ions for energy deposits up to 661.7 keV, consistent with previous LUX measurements between 2-16 keV with $^3$H. We highlight similarities in liquid xenon recombination for electronic and nuclear recoils with a comparison of recombination fluctuations measured with low-energy calibration data.<br />11 pages, 12 figures, 3 tables

Details

Language :
English
Database :
OpenAIRE
Journal :
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos), Agência para a Sociedade do Conhecimento (UMIC)-FCT-Sociedade da Informação, instacron:RCAAP, BASE-Bielefeld Academic Search Engine
Accession number :
edsair.doi.dedup.....b651096448b9faf0ebd1393ee258a5d8