Back to Search
Start Over
Cluster of pseudoinfections with Burkholderia cepacia associated with a contaminated washer-disinfector in a bronchoscopy unit
- Source :
- Infection control and hospital epidemiology. 31(7)
- Publication Year :
- 2010
-
Abstract
- In December 2008, bronchoalveolar lavage fluid samples obtained from 3 patients were positive forBurkholderia cepaciacomplex on culture. Samples obtained from bronchoscopes and rinse-water samples obtained from the washer-disinfector were found to be positive forB. cepaciacomplex. The cause of this pseudo-outbreak was that the washer-disinfector was installed without the required antibacterial filter.
- Subjects :
- Microbiology (medical)
Male
Epidemiology
Bronchoscopy Unit
Microbial contamination
Burkholderia cepacia
Microbiology
Disease Outbreaks
Bronchoscopy
medicine
Humans
Bronchoscopes
Israel
Academic Medical Centers
Cross Infection
medicine.diagnostic_test
biology
business.industry
Burkholderia Infections
Contamination
Middle Aged
biology.organism_classification
Disinfection
Burkholderia cepacia complex
Infectious Diseases
Bronchoalveolar lavage
Burkholderia
Equipment Contamination
business
Water Microbiology
Bronchoalveolar Lavage Fluid
Hospital Units
Subjects
Details
- ISSN :
- 15596834
- Volume :
- 31
- Issue :
- 7
- Database :
- OpenAIRE
- Journal :
- Infection control and hospital epidemiology
- Accession number :