In vivo testing of the low-flow CO2 removal application of a compact, platform respiratory device
- Source :
- Intensive Care Medicine Experimental, Vol 8, Iss 1, Pp 1-11 (2020)
- Publication Year :
- 2020
- Publisher :
- SpringerOpen, 2020.
-
Abstract
- Background Non-invasive and lung-protective ventilation techniques may improve outcomes for patients with an acute exacerbation of chronic obstructive pulmonary disease or moderate acute respiratory distress syndrome by reducing airway pressures. These less invasive techniques can fail due to hypercapnia and require transitioning patients to invasive mechanical ventilation. Extracorporeal CO2 removal devices remove CO2 independent of the lungs thereby controlling the hypercapnia and permitting non-invasive or lung-protective ventilation techniques. We are developing the Modular Extracorporeal Lung Assist System as a platform technology capable of providing three levels of respiratory assist: adult and pediatric full respiratory support and adult low-flow CO2 removal. The objective of this study was to evaluate the in vivo performance of our device to achieve low-flow CO2 removal. Methods The Modular Extracorporeal Lung Assist System was connected to 6 healthy sheep via a 15.5 Fr dual-lumen catheter placed in the external jugular vein. The animals were recovered and tethered within a pen while supported by the device for 7 days. The pump speed was set to achieve a targeted blood flow of 500 mL/min. The extracorporeal CO2 removal rate was measured daily at a sweep gas independent regime. Hematological parameters were measured pre-operatively and regularly throughout the study. Histopathological samples of the end organs were taken at the end of each study. Results All animals survived the surgery and generally tolerated the device well. One animal required early termination due to a pulmonary embolism. Intra-device thrombus formation occurred in a single animal due to improper anticoagulation. The average CO2 removal rate (normalized to an inlet pCO2 of 45 mmHg) was 75.6 ± 4.7 mL/min and did not significantly change over the course of the study (p > 0.05). No signs of consistent hemolysis or end organ damage were observed. Conclusion These in vivo results indicate positive performance of the Modular Extracorporeal Lung Assist System as a low-flow CO2 removal device.
- Subjects :
- Acute exacerbation of chronic obstructive pulmonary disease
medicine.medical_treatment
Critical Care and Intensive Care Medicine
Extracorporeal
Hypercapnia
03 medical and health sciences
0302 clinical medicine
medicine
Respiratory system
Mechanical ventilation
Lung
business.industry
lcsh:Medical emergencies. Critical care. Intensive care. First aid
030208 emergency & critical care medicine
Extracorporeal CO2 removal
lcsh:RC86-88.9
medicine.disease
Pulmonary embolism
medicine.anatomical_structure
030228 respiratory system
Carbon dioxide
Anesthesia
Breathing
medicine.symptom
business
Subjects
Details
- Language :
- English
- Volume :
- 8
- Issue :
- 1
- Database :
- OpenAIRE
- Journal :
- Intensive Care Medicine Experimental
- Accession number :
- edsair.doi.dedup.....b9d4614fef26410ee6f9c6493afdf53b