Back to Search
Start Over
Location of Reentry Tears Affects False Lumen Thrombosis in Aortic Dissection Following TEVAR
- Source :
- Journal of Endovascular Therapy
- Publication Year :
- 2020
- Publisher :
- SAGE Publications, 2020.
-
Abstract
- Purpose: To report a study that assesses the influence of the distance between the distal end of a thoracic stent-graft and the first reentry tear (SG-FRT) on the progression of false lumen (FL) thrombosis in patients who underwent thoracic endovascular aortic repair (TEVAR). Materials and Methods: Three patient-specific geometrical models were reconstructed from postoperative computed tomography scans. Two additional models were created by artificially changing the SG-FRT distance in patients 1 and 2. In all 5 models, computational fluid dynamics simulations coupled with thrombus formation modeling were performed at physiological flow conditions. Predicted FL thrombosis was compared to follow-up scans. Results: There was reduced false lumen flow and low time-averaged wall shear stress (TAWSS) in patients with large SG-FRT distances. Predicted thrombus formation and growth were consistent with follow-up scans for all patients. Reducing the SG-FRT distance by 30 mm in patient 1 increased the flow and time-averaged wall shear stress in the upper abdominal FL, reducing the thrombus volume by 9.6%. Increasing the SG-FRT distance in patient 2 resulted in faster thoracic thrombosis and increased total thrombus volume. Conclusion: The location of reentry tears can influence the progression of FL thrombosis following TEVAR. The more distal the reentry tear in the aorta the more likely it is that FL thrombosis will occur. Hence, the distal landing zone of the stent-graft should be chosen carefully to ensure a sufficient SG-FRT distance.
- Subjects :
- reentry tear
Patient-Specific Modeling
IMPACT
Computed Tomography Angiography
False lumen
endovascular procedures
patient-specific geometrical models
false lumen
Risk Factors
aortic dissection
PREDICTORS
Aortic dissection
RISK
Models, Cardiovascular
Reentry
Thrombosis
MEDICAL-TREATMENT
Treatment Outcome
Physiological flow
cardiovascular system
Stents
Radiology
Thoracic and Thoracoabdominal Aortic Interventions
Cardiology and Cardiovascular Medicine
Life Sciences & Biomedicine
medicine.medical_specialty
computational fluid dynamics
Vascular Remodeling
Prosthesis Design
Aortography
thoracic endovascular aortic repair
Blood Vessel Prosthesis Implantation
medicine.artery
medicine
MANAGEMENT
Humans
Radiology, Nuclear Medicine and imaging
Thrombus
thrombosis
stent-graft
Aorta
Science & Technology
Aortic Aneurysm, Thoracic
business.industry
Hemodynamics
ENDOVASCULAR REPAIR
1103 Clinical Sciences
medicine.disease
Blood Vessel Prosthesis
Peripheral Vascular Disease
Cardiovascular System & Hematology
Cardiovascular System & Cardiology
Tears
Surgery
business
Subjects
Details
- Language :
- English
- ISSN :
- 15451550 and 15266028
- Volume :
- 27
- Issue :
- 3
- Database :
- OpenAIRE
- Journal :
- Journal of Endovascular Therapy
- Accession number :