Back to Search
Start Over
Feasibility of bioelectrical impedance analysis in persons with severe intellectual and visual disabilities
- Source :
- Research in Developmental Disabilities, 47, 126-134. Elsevier, Research in Developmental Disabilities, 47, 126-134. PERGAMON-ELSEVIER SCIENCE LTD
- Publication Year :
- 2015
-
Abstract
- Background: Body composition measurements provide important information about physical fitness and nutritional status. People with severe intellectual and visual disabilities (SIVD) have an increased risk for altered body composition. Bioelectrical impedance analysis (BIA) has been evidenced as a reliable and non-invasive method to asses body composition in healthy persons and various patient populations; however, currently, there is no feasible method available to determine body composition in people with SIVD. In this study, therefore, we aimed to assess the feasibility of BIA measurements in persons with SIVD.Methods: In 33 participants with SIVD and Gross Motor Functioning Classification System (GMFCS) Scale I, II, III, or IV, two BIA measurements were sequentially performed employing Resistance and Reactance in Ohm and fat-free mass (FFM) in kg as outcome variables, utilizing the Bodystat (R) QuadScan 4000. Feasibility was considered sufficient if >= 80% of the first measurement was performed successfully. Agreement between two repeated measurements was determined by using the paired t-test and Intraclass Correlation Coefficient (ICC; two way random, absolute agreement). Bland-Altman analyses were utilized to determine limits of agreement (LOAs) and systematic error. Agreement was considered acceptable if LOAs wereResults: The first BIA measurements were completed successfully in 88% of the participants. The paired t-test demonstrated no significant differences in Resistance, Reactance, and FFM between BIA Measurements 1 and 2 (P= 0.140, 0.091, and 0.866). ICC was 0.965 (95% CI: 0.922-0.984) for Resistance; 0.858 (95% CI: 0.705-0.934) for Reactance; and 0.992 (95% CI: 0.982-0.996) for FFM. LOAs expressed as a percentage of the mean of Measurement 1 were 6.1% for Resistance, 17.6% for Reactance, and 3.8% for FFM.Conclusions: The results of this study suggest that BIA measurements seem to be feasible in persons with SIVD. Although these results require confirmation in a more extensive sample of persons with SIVD, the findings of this study are an important first step in the assessment of applicability of BIA measurements for non-invasive monitoring of physical fitness and nutritional status of persons with SIVD. (C) 2015 Elsevier Ltd. All rights reserved.
- Subjects :
- Adult
Male
medicine.medical_specialty
BODY-COMPOSITION
Intraclass correlation
Reactance
Gross motor skill
Physical fitness
Vision Disorders
CHILDREN
Severity of Illness Index
Residential Facilities
haalbaarheidsstudie
Physical medicine and rehabilitation
PEOPLE
Intellectual Disability
Severity of illness
Developmental and Educational Psychology
Electric Impedance
Medicine
Humans
VALIDITY
Netherlands
business.industry
Limits of agreement
feasibility study
Reproducibility of Results
ADULTS
IMPAIRMENT
Middle Aged
Clinical Psychology
Increased risk
verstandelijk gehandicapten
CLINICAL-PRACTICE
OBESITY
gezichtsstoornissen
RELIABILITY
Physical therapy
Body Composition
Feasibility Studies
NUTRITION
Female
business
Bioelectrical impedance analysis
lichaamssamenstelling
Subjects
Details
- ISSN :
- 18733379 and 08914222
- Volume :
- 47
- Database :
- OpenAIRE
- Journal :
- Research in developmental disabilities
- Accession number :
- edsair.doi.dedup.....bb9caeba7f1cabac951678aa99313512