Back to Search Start Over

Feasibility of bioelectrical impedance analysis in persons with severe intellectual and visual disabilities

Authors :
van der Cornelis Schans
A. M. Havinga-Top
Aly Waninge
H. Jager-Wittenaar
Participation and Health of Persons with Intellectual and Visual Disabilities
Healthy Ageing, Allied Health Care and Nursing
Malnutrition and Healthy Ageing
Extremities Pain and Disability (EXPAND)
Source :
Research in Developmental Disabilities, 47, 126-134. Elsevier, Research in Developmental Disabilities, 47, 126-134. PERGAMON-ELSEVIER SCIENCE LTD
Publication Year :
2015

Abstract

Background: Body composition measurements provide important information about physical fitness and nutritional status. People with severe intellectual and visual disabilities (SIVD) have an increased risk for altered body composition. Bioelectrical impedance analysis (BIA) has been evidenced as a reliable and non-invasive method to asses body composition in healthy persons and various patient populations; however, currently, there is no feasible method available to determine body composition in people with SIVD. In this study, therefore, we aimed to assess the feasibility of BIA measurements in persons with SIVD.Methods: In 33 participants with SIVD and Gross Motor Functioning Classification System (GMFCS) Scale I, II, III, or IV, two BIA measurements were sequentially performed employing Resistance and Reactance in Ohm and fat-free mass (FFM) in kg as outcome variables, utilizing the Bodystat (R) QuadScan 4000. Feasibility was considered sufficient if >= 80% of the first measurement was performed successfully. Agreement between two repeated measurements was determined by using the paired t-test and Intraclass Correlation Coefficient (ICC; two way random, absolute agreement). Bland-Altman analyses were utilized to determine limits of agreement (LOAs) and systematic error. Agreement was considered acceptable if LOAs wereResults: The first BIA measurements were completed successfully in 88% of the participants. The paired t-test demonstrated no significant differences in Resistance, Reactance, and FFM between BIA Measurements 1 and 2 (P= 0.140, 0.091, and 0.866). ICC was 0.965 (95% CI: 0.922-0.984) for Resistance; 0.858 (95% CI: 0.705-0.934) for Reactance; and 0.992 (95% CI: 0.982-0.996) for FFM. LOAs expressed as a percentage of the mean of Measurement 1 were 6.1% for Resistance, 17.6% for Reactance, and 3.8% for FFM.Conclusions: The results of this study suggest that BIA measurements seem to be feasible in persons with SIVD. Although these results require confirmation in a more extensive sample of persons with SIVD, the findings of this study are an important first step in the assessment of applicability of BIA measurements for non-invasive monitoring of physical fitness and nutritional status of persons with SIVD. (C) 2015 Elsevier Ltd. All rights reserved.

Details

ISSN :
18733379 and 08914222
Volume :
47
Database :
OpenAIRE
Journal :
Research in developmental disabilities
Accession number :
edsair.doi.dedup.....bb9caeba7f1cabac951678aa99313512