Initial Clinical Experience With a New Conformable Abdominal Aortic Endograft: Aortic Neck Coverage and Curvature Analysis in Challenging Aortic Necks
- Source :
- Journal of Endovascular Therapy, 28(3), 407-414. SAGE Publications Inc.
- Publication Year :
- 2021
- Publisher :
- SAGE Publications Inc., 2021.
-
Abstract
- Objectives: Aim of this work was to investigate precision of deployment and conformability of a new generation GORE EXCLUDER Conformable Endoprosthesis with active control system (CEXC Device, W.L. Gore and Associates, Flagstaff, AZ, USA) by analyzing aortic neck coverage and curvature. Methods: All consecutive elective patients affected by abdominal aortic aneurysm or aortoiliac aneurysm treated at our institution between November 2018 and June 2019 with the new CEXC Device were enrolled. Validated software was adopted to determine the available apposition surface area into the aortic neck, apposition of the endograft to the aortic wall, shortest apposition length (SAL), shortest distance between the endograft fabric and the lowest renal arteries (SFD) and between the endograft fabric and the contralateral renal artery (CFD). Pointwise centerline curvature was also computed. Results: Twelve patients (10 men, median age 78 years (71.75, 81.0)) with available pre- and postoperative computed tomography angiography (CTA) were included. Technical success was obtained in all the cases. Preoperative median length of the proximal aortic neck was 16.1 mm (10.7, 21.7) and suprarenal (α) and infrarenal (β) neck angulation were, respectively, 28.9° (15.7°, 47.5°) and 75.0° (66.9°, 81.4°). Postoperative median apposition surface coverage was 79% (69.25%, 90.75%) of the available apposition surface. SFD and CFD were 1.5 mm (0.75, 5.25) and 7 mm (4.5, 21.5), respectively. Average curvature over the infrarenal aorta decreased from 25 m−1 (21.75, 29.0) to 22.5 m−1 (18.75, 24.5) postoperatively (p=0.02). Maximum curvature did not decrease significantly from 64.5 m−1 (54.25, 92.0) to 62 m−1 (41.75, 71.5) (p=0.1). Conclusions: Our early experience showed that deployment of the CEXC Device is safe and effective for patients with challenging proximal aortic necks. Absence of significant changes between pre- and postoperative proximal aortic neck angulations and curvature confirms the high conformability of this endograft.
- Subjects :
- endovascular treatment
Male
medicine.medical_specialty
Time Factors
Prosthesis Design
Aortography
Blood Vessel Prosthesis Implantation
abdominal aortic aneurysm
Medicine
Humans
Radiology, Nuclear Medicine and imaging
Abdominal
Aorta, Abdominal
Endovascular treatment
Aorta
Aged
Retrospective Studies
business.industry
Endovascular Procedures
Conformable matrix
apposition
geometric analysis
sealing
Blood Vessel Prosthesis
Treatment Outcome
Aortic Aneurysm, Abdominal
Active control
medicine.disease
Abdominal aortic aneurysm
Aortic Aneurysm
Surgery
Radiology
Curvature analysis
Cardiology and Cardiovascular Medicine
business
Aortic neck
Subjects
Details
- Language :
- English
- ISSN :
- 15266028
- Database :
- OpenAIRE
- Journal :
- Journal of Endovascular Therapy, 28(3), 407-414. SAGE Publications Inc.
- Accession number :