Trueness of a device for intraoral scanning to capture the angle and distance between implants in edentulous mandibular arches

Authors :
Rodrigo Falcão Carvalho Porto de Freitas
Ana Clara Soares Paiva Tôrres
Adriana da Fonte Porto Carreiro
Annie Karoline Bezerra de Medeiros
Maria de Fátima Trindade Pinto Campos
Ana Larisse Carneiro Pereira
Source :
The Journal of Prosthetic Dentistry. 128:1310-1317
Publication Year :
2022
Publisher :
Elsevier BV, 2022.

Abstract

Statement of problem The digitalization of completely edentulous arches presents limitations because of the lack of anatomic structures for best-fit alignment during the image generation process of the scanner’s software program. Purpose The purpose of this clinical study was to evaluate a new device for intraoral scanning and to analyze its usefulness in capturing the 3-dimensional (3D) position of implants in edentulous mandibular arches. Material and methods The 3D positions of 40 implants in 10 participants with fixed interim mandibular prostheses were evaluated by comparing 3 scanning techniques. Images were generated in 2 experimental groups, with digital scan bodies (group SC) and with the scanning device (group SD) and in a control group (group CT) in which images were obtained by laboratory scanning of casts produced from splinted impression copings. The standard tessellation language (STL) files were superimposed by using a reverse engineering software program to measure the 3D coordinate system. Variations in implant linear displacements (Δx, Δy, and Δz), total 3D displacement ( Δ x 2 + Δ y 2 + Δ z 2 ), and angle projections (ΔθXY, ΔθXZ, and ΔθYZ) were statistically analyzed (α=.05). The distances between the implants were also measured. The Spearman correlation coefficient (α=.05) was used to find the correlation between the 3D coordinates and the distances between the implants. Results Group SD had lower values for linear displacement than group SC; however, this difference was not statistically significant except for implant #2. The overall evaluation showed a significant difference with better accuracy for group SD. Concerning angular displacements, group SD showed lesser angular variation for the 3 projection planes. For the distances between the implants, significant differences were only observed for the “all” assessment in which group SD behaved similarly to group CT, while group SC showed the highest values (P Conclusions The evaluated scanning device led to improved trueness for linear, angular displacements, and distances between implants in mandibular edentulous arches.

Details

ISSN :
00223913
Volume :
128
Database :
OpenAIRE
Journal :
The Journal of Prosthetic Dentistry
Accession number :
edsair.doi.dedup.....bd2e34e9450d457e4240502206f81301