Back to Search
Start Over
The effect of an aerobic training program on the electrical remodeling of heart high-frequency components of the signal-averaged electrocardiogram is a predictor of the maximal aerobic power
- Source :
- Brazilian Journal of Medical and Biological Research, Volume: 40, Issue: 2, Pages: 199-208, Published: 07 JAN 2007, Brazilian Journal of Medical and Biological Research v.40 n.2 2007, Brazilian Journal of Medical and Biological Research, Associação Brasileira de Divulgação Científica (ABDC), instacron:ABDC, Brazilian Journal of Medical and Biological Research, Vol 40, Iss 2, Pp 199-208 (2007)
- Publication Year :
- 2006
-
Abstract
- Increased heart rate variability (HRV) and high-frequency content of the terminal region of the ventricular activation of signal-averaged ECG (SAECG) have been reported in athletes. The present study investigates HRV and SAECG parameters as predictors of maximal aerobic power (VO2max) in athletes. HRV, SAECG and VO2max were determined in 18 high-performance long-distance (25 ± 6 years; 17 males) runners 24 h after a training session. Clinical visits, ECG and VO2max determination were scheduled for all athletes during thew training period. A group of 18 untrained healthy volunteers matched for age, gender, and body surface area was included as controls. SAECG was acquired in the resting supine position for 15 min and processed to extract average RR interval (Mean-RR) and root mean squared standard deviation (RMSSD) of the difference of two consecutive normal RR intervals. SAECG variables analyzed in the vector magnitude with 40-250 Hz band-pass bi-directional filtering were: total and 40-µV terminal (LAS40) duration of ventricular activation, RMS voltage of total (RMST) and of the 40-ms terminal region of ventricular activation. Linear and multivariate stepwise logistic regressions oriented by inter-group comparisons were adjusted in significant variables in order to predict VO2max, with a P < 0.05 considered to be significant. VO2max correlated significantly (P < 0.05) with RMST (r = 0.77), Mean-RR (r = 0.62), RMSSD (r = 0.47), and LAS40 (r = -0.39). RMST was the independent predictor of VO2max. In athletes, HRV and high-frequency components of the SAECG correlate with VO2max and the high-frequency content of SAECG is an independent predictor of VO2max.
- Subjects :
- Adult
Male
medicine.medical_specialty
Supine position
Long-distance runners
Ocean Engineering
Standard deviation
Running
Electrocardiography
Mathematical model
Oxygen Consumption
Heart Rate
Predictive Value of Tests
Internal medicine
Heart rate
Medicine
Aerobic exercise
Humans
lcsh:QH301-705.5
Body surface area
lcsh:R5-920
Maximal aerobic power
medicine.diagnostic_test
business.industry
Signal Processing, Computer-Assisted
Models, Theoretical
Signal-averaged electrocardiogram
Surgery
lcsh:Biology (General)
Case-Control Studies
RMST
Cardiology
Physical Endurance
Female
lcsh:Medicine (General)
business
human activities
Subjects
Details
- ISSN :
- 0100879X
- Volume :
- 40
- Issue :
- 2
- Database :
- OpenAIRE
- Journal :
- Brazilian journal of medical and biological research = Revista brasileira de pesquisas medicas e biologicas
- Accession number :
- edsair.doi.dedup.....bd7ade92ef024a0d17dad0d0c3427c87