Diagnostic value of real-time elastography in the assessment of hepatic fibrosis in patients with liver iron overload
- Source :
- European Journal of Radiology. 82:e755-e761
- Publication Year :
- 2013
- Publisher :
- Elsevier BV, 2013.
-
Abstract
- The objective of our prospective monocentric work was to determine the diagnostic value of real-time elastography (RTE) in the assessment of liver fibrosis in patients with iron overload, using transient elastography (TE) as reference standard.Sixty-seven consecutive patients with MRI detectable iron overload (T2*6.3 ms) were enrolled. TE and RTE were performed on the same day as MRI. Elastograms were acquired by an experienced operator and analyzed by calculating the elastic ratio between perihepatic soft tissues and liver parenchyma. An elliptical ROI of 1cm(2) (Z1) was positioned in the liver parenchyma and a smaller elliptical ROI of 2mm(2) (Z2) was positioned in a homogeneously soft (red) region of the diaphragm, which was considered as internal control to calculate the elastic ratio Z2/Z1.Seven patients were excluded because of invalid TE or RTE examinations. The remaining 60 patients were 57% males and 43% females (mean age: 42 [21-76] years), including 37 homozygous-β-thalassemics, 13 patients with β-thalassemia intermedia, 6 with primary hemochromatosis, and 4 with myelodysplastic syndrome. Increasing elastic ratios were significantly correlated with increasing TE values (r=0.645, 95% CI 0.468-0.772, P0.0001). The mean elastic ratios for each METAVIR group were as follows: F0/1 = 1.9 ± 0.4; F2 = 2.2 ± 0.4; F3 = 2.9 ± 0.5; F4 = 3.2 ± 0.4. The diagnostic accuracy of RTE for F ≥ 2 evaluated by AUC-ROC analysis was 0.798 (95% CI 0.674-0.890). The diagnostic accuracy of RTE for F ≥ 3 was 0.909 (95% CI 0.806-0.968). At a cut-off ≥ 2.75, RTE showed a sensitivity of 70% (95% CI 45.7-88.1) and a specificity of 97.5% (95% CI 86.8-99.9).In patients with MRI-detectable liver iron-overload RTE allows to discriminate between F0/1-F2 and F3-F4 with a reasonable diagnostic accuracy.
- Subjects :
- Adult
Liver Cirrhosis
Male
medicine.medical_specialty
Iron Overload
Thalassemia
Sensitivity and Specificity
Gastroenterology
Computer Systems
Internal medicine
Humans
Medicine
Radiology, Nuclear Medicine and imaging
In patient
Real time elastography
Hemochromatosis
Aged
medicine.diagnostic_test
business.industry
Ultrasound
Reproducibility of Results
General Medicine
Middle Aged
medicine.disease
Elasticity Imaging Techniques
Female
Elastography
Hepatic fibrosis
business
Transient elastography
Subjects
Details
- ISSN :
- 0720048X
- Volume :
- 82
- Database :
- OpenAIRE
- Journal :
- European Journal of Radiology
- Accession number :
- edsair.doi.dedup.....c04535c33a5756fe4b41f6476f50823b
- Full Text :
- https://doi.org/10.1016/j.ejrad.2013.08.038