Real-time control of angioplasty balloon inflation based on feedback from intravascular optical coherence tomography: Experimental validation on an excised heart and a beating heart model
- Publication Year :
- 2012
-
Abstract
- We report on real-time control of balloon inflation inside porcine arteries. In the first step, experiments were done in a coronary artery of an excised heart. In the second step, experiments were done in a beating heart setup providing conditions very close to in vivo conditions without the complications. A programmable syringe pump was used to inflate a compliant balloon in arteries, while intravascular optical coherence tomography (IVOCT) monitoring was performed. In a feedback loop, IVOCT images were processed to provide the balloon diameter values in real time to control the pump action in order to achieve a target diameter. In different experiments, various flow rates and target diameters were used. In the excised heart experiment, there was good convergence to target diameters resulting in a satisfactory balloon inflation control. In the beating heart experiment, there were oscillations in the diameter values due to cyclic arterial contractions. In these experiments, the control system maintained diameter averages satisfactorily close to predetermined target values. Real-time control of balloon inflation could not only provide a safer outcome for angioplasty procedures, but could also provide additional information for diagnostics since it implicitly provides information about the artery response to the inflation process. © 1964-2012 IEEE.
- Subjects :
- Swine
medicine.medical_treatment
Balloon
Beating heart
feedback system
Inflation process
Feed-back loop
Balloons
medicine.diagnostic_test
Models, Cardiovascular
Heart
balloon catheter
Real time
medicine.anatomical_structure
Experimental validations
Programmable syringe pump
Cardiology
Tomography
flow rate
control system
Algorithms
Tomography, Optical Coherence
Artery
medicine.medical_specialty
animal experiment
Biomedical Engineering
percutaneous transluminal angioplasty
Feedback
Coronary arteries
Optical coherence tomography
In-vivo
Internal medicine
Angioplasty
heart beat
Control
syringe
medicine
Pressure
Animals
Optical tomography
Syringe driver
Balloon inflation
optical coherence tomography
business.industry
artery constriction
Real time control
Target values
heart surgery
Control system
Intravascular
business
Experiments
Angioplasty, Balloon
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Accession number :
- edsair.doi.dedup.....c0827db39c5bd3d25a3ad36ce0e21226