Frontiers in Neurology, r-FISABIO. Repositorio Institucional de Producción Científica, instname, Frontiers in Neurology, Vol 10 (2019), r-FISABIO: Repositorio Institucional de Producción Científica, Fundación para el Fomento de la Investigación Sanitaria y Biomédica de la Comunitat Valenciana (FISABIO)
Publication Year :
2019
Publisher :
FRONTIERS MEDIA SA, 2019.

Abstract

The development of wearable devices has increase interest in the use of ambulatory methods to detect sleep disorders more objectively than those permitted by subjective scales evaluating sleep quality, while subjects maintain their usual lifestyle. This study aims to validate an ambulatory circadian monitoring (ACM) device for the detection of sleep and wake states and apply it to the evaluation of sleep quality in patients with Parkinson disease (PD). A polysomnographic validation study was conducted on a group of patients with different sleep disorders in a preliminary phase, followed by a pilot study to apply this methodology to PD patients. The ACM device makes it possible to estimate the main sleep parameters very accurately, as demonstrated by: (a) the lack of significant differences between the mean values detected by PSG and ACM in time in bed (TIB), total sleep time (TST), sleep efficiency (SE), and time awake after sleep onset (WASO); (b) the slope of the correlation lines between the parameters estimated by the two procedures, very close to 1, which demonstrates the linearity of the predictions; (c) the low bias value in the estimates obtained through ACM. Sleep in PD is associated with lower distal skin temperature, efficiency and overall sleep time; greater WASO, activity during sleep and duration of naps and a worse circadian function index. In summary, the ACM device has proven to be clinically useful to evaluate sleep in an objective manner, thanks to the integrated management of different complementary variables, having advantages over conventional actigraphy.

Details

ISSN :
16642295
Database :
OpenAIRE
Journal :
Frontiers in Neurology, r-FISABIO. Repositorio Institucional de Producción Científica, instname, Frontiers in Neurology, Vol 10 (2019), r-FISABIO: Repositorio Institucional de Producción Científica, Fundación para el Fomento de la Investigación Sanitaria y Biomédica de la Comunitat Valenciana (FISABIO)
Accession number :
edsair.doi.dedup.....c23781c672f88762fd42d10317690f05