Back to Search
Start Over
Reliability, Validity, and Responsiveness of Myotonometric Measurement of Muscle Tone, Elasticity, and Stiffness in Patients With Stroke
- Source :
- Archives of Physical Medicine and Rehabilitation. 93:532-540
- Publication Year :
- 2012
- Publisher :
- Elsevier BV, 2012.
-
Abstract
- Chuang L-L, Wu C-Y, Lin K-C. Reliability, validity, and responsiveness of myotonometric measurement of muscle tone, elasticity, and stiffness in patients with stroke. Objective To assess the metric properties of a myotonometer. Design Metric study. Setting Three medical centers. Participants Stroke patients (N=67). Intervention Upper-extremity rehabilitation programs. Main Outcome Measures The tone, elasticity, and stiffness of relaxed extensor digitorum, flexor carpi radialis, and flexor carpi ulnaris were measured using the myotonometer. Fifty-eight patients completed the myotonometer measures twice at pretreatment. The myotonometric measurement and the criteria measures, including hand strength (grip, lateral pinch, and palmar pinch strength) and Action Research Arm Test (ARAT) were administered at pretreatment and posttreatment. Results The myotonometer showed high test-retest reliability for muscle properties in 3 muscles. Significant correlations existed between the tone and stiffness of the 3 muscles and palmar pinch strength, between those of the flexor carpi muscles and lateral pinch strength, and between those of the flexor carpi radialis and the ARAT at posttreatment. The posttreatment elasticity of the 2 flexor carpi muscles was significantly correlated with grip strength. The pretreatment elasticity of the flexor carpi ulnaris was significantly correlated with posttreatment grip strength, and the pretreatment muscle tone and stiffness of the flexor carpi radialis were significantly correlated with palmar pinch strength and the ARAT. The responsiveness of the extensor digitorum was higher than that of the flexor carpi radialis and ulnaris. Muscle stiffness was more responsive than tone and elasticity in 3 muscles. Conclusions Myotonometry can be a reliable, valid, and responsive outcome measure for assessing muscle properties after stroke rehabilitation.
- Subjects :
- Adult
Male
medicine.medical_specialty
Biometry
Flexor Carpi Ulnaris
Intraclass correlation
Modified Ashworth scale
Physical Therapy, Sports Therapy and Rehabilitation
Pinch Strength
Upper Extremity
Muscle tone
Grip strength
Physical medicine and rehabilitation
Hand strength
medicine
Humans
Muscle, Skeletal
Aged
Hand Strength
business.industry
Rehabilitation
Stroke Rehabilitation
Reproducibility of Results
Middle Aged
Muscle stiffness
musculoskeletal system
Elasticity
Stroke
body regions
medicine.anatomical_structure
Physical therapy
Female
business
Subjects
Details
- ISSN :
- 00039993
- Volume :
- 93
- Database :
- OpenAIRE
- Journal :
- Archives of Physical Medicine and Rehabilitation
- Accession number :
- edsair.doi.dedup.....c2f9fe283940ab871fcf3ec49359c0fd