Internal thoracic artery graft (ITAG): patency and functional status at rest and during dobutamine-stress echocardiography

Authors :
Marília Esther Benevides de Abreu
José Maria Bonfim de Morais
José Erirtônio Façanha Barreto
José Nogueira Paes Júnior
Tereza Cristina Pinheiro Diógenes
André Luís de Castro Abreu
Jorge Henrique Azevedo Pinto
José Sebastião de Abreu
Source :
Arquivos Brasileiros de Cardiologia, Volume: 90, Issue: 1, Pages: 37-45, Published: JAN 2008, Arquivos Brasileiros de Cardiologia v.90 n.1 2008, Arquivos Brasileiros de Cardiologia, Sociedade Brasileira de Cardiologia (SBC), instacron:SBC
Publication Year :
2008
Publisher :
FapUNIFESP (SciELO), 2008.

Abstract

FUNDAMENTO: A artéria torácica interna enxertada (ATIE) patente usualmente tem fração diastólica (FD)> 50% do fluxo. O estado funcional pode ser avaliado pelo índice de reserva coronariano (IRC). OBJETIVO: Avaliar, pela ecocardiografia e pelo Doppler em nível supraclavicular, a patência e o estado funcional da ATIE. MÉTODOS: Foram coletados prospectivamente e analisados os dados de 66 pacientes submetidos a ecocardiograma sob estresse com dobutamina (EED). O grupo I (GI) ocorreu com 49 ATIE sem estenose. No grupo II (GII) (10 ATIE) havia estenose significativa (> 50% e 50%, ocorreu em 49 ATIE (GI=40, GII=8 e GIII=1) no repouso e em 61 ATIE (GI=49, GII=10 e GIII=2) durante EED. Sensibilidade, especificidade, valor preditivo positivo (VPP), valor preditivo negativo (VPN) e acurácia foram, respectivamente, em repouso, 81%, 86% ,98%, 35 % e 82%; e no EED, 100%, 71%, 97%, 100% e 97%. As ATIE com FD>50% em repouso estavam patentes e as com FD1,8, isso ocorreu em 42 ATIE (39 do GI, 2 do GII e 1 GIII), verificando-se sensibilidade = 79%; especificidade = 85,7%; VPP = 94%; VPN = 59%; e acurácia = 80,9%. O IRC no GI foi maior (p=0,02) que em GII e GIII. CONCLUSÃO: Em nosso estudo, a avaliação não-invasiva da ATIE foi efetiva para verificar patência e estado funcional. BACKGROUND: The patent internal thoracic artery graft (ITAG) usually has a diastolic fraction (DF) > 50% of the flow. The functional assessment can be evaluated by the coronary reserve index (CRI). OBJECTIVE: The objective was to evaluate the patency and functional status of the ITAG through echocardiography and Doppler. METHODS: Data from sixty-six patients who underwent dobutamine-stress echocardiography (DSE) were prospectively collected and analyzed. Group I (GI) had 49 ITAG without stenosis, Group II (GII), 10 ITAG with significant stenosis (> 50% and 50%, it was observed in 49 ITAG (GI= 40, GII= 8 and GIII= 1) at rest and in 61 ITAG (GI=49, GII=10 and GIII=2) during DSE. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy were respectively, 81%, 86%, 98%, 35% and 82%, and 100%, at rest and 71%, 97%, 100% and 97% in the DSE. The ITAG with DF>50% at rest were patent and the ones with DF1.8 for a good functional status, it was observed in 42 ITAG (39 from GI, 2 from GII and 1 from GIII), determining sensitivity=79%, specificity=85.7%, PPV=94%, NPV=59% and accuracy= 80.9%. The CRI in GI was higher (p= 0.02) than in GII or GIII. CONCLUSION: In our study, the non-invasive assessment of the ITAG was effective to verify the patency and the functional status.

Details

ISSN :
0066782X
Volume :
90
Database :
OpenAIRE
Journal :
Arquivos Brasileiros de Cardiologia
Accession number :
edsair.doi.dedup.....c34295bcf132440783178368a2a5c515
Full Text :
https://doi.org/10.1590/s0066-782x2008000100007