Back to Search
Start Over
Technical safety and efficacy of a blunt-tip microwave ablation electrode for CT-guided ablation of pulmonary ground-glass opacity nodules
- Source :
- European Radiology. 31:7484-7490
- Publication Year :
- 2021
- Publisher :
- Springer Science and Business Media LLC, 2021.
-
Abstract
- To evaluate the safety and technical efficacy of a customized blunt-tip microwave ablation (MWA) electrode for CT-guided ablation of pulmonary ground-glass opacity nodules (GGOs). This was a retrospective before-after study. All consented patients with GGOs who underwent MWA treatment using conventional sharp-tip electrodes (group A) between January 2018 and December 2018 or new blunt-tip electrodes (group B) between January 2019 and December 2019 in our institution were included. The individual features of each patient and lesion, as well as technical and clinical information, were collected and analyzed. Sixteen (7 males, 9 females; mean age, 64.9 ± 12.3 years) and twenty-six (11 males, 15 females; mean age, 66.5 ± 10.7 years) patients were enrolled in groups A and B, respectively. The technique was successfully performed in all patients and a follow-up CT scan at 24 h after MWA showed that the technical efficacy rate was 100% in both groups. Twelve (75.0%) grade I complications were noted in group A, whereas 11 (42.3%) were noted in group B (p = 0.039, chi-square test). No bleeding occurred within the lesions in group B. The blunt-tip MWA electrode is a safe and technically effective tool for ablating GGO lesions. • A new blunt-tip MWA electrode was used for CT-guided ablation of GGO lesions. • The blunt-tip MWA electrode could improve the safety of GGO ablation. • The technical efficacy of ablation was maintained by using the blunt-tip MWA electrode.
- Subjects :
- Ablation Techniques
Male
medicine.medical_specialty
Lung Neoplasms
medicine.medical_treatment
Ground-glass opacity
030218 nuclear medicine & medical imaging
03 medical and health sciences
0302 clinical medicine
Blunt
medicine
Humans
Radiology, Nuclear Medicine and imaging
Microwaves
Electrodes
Aged
Retrospective Studies
Neuroradiology
medicine.diagnostic_test
business.industry
Ultrasound
Microwave ablation
Interventional radiology
General Medicine
Middle Aged
Ablation
Treatment Outcome
030220 oncology & carcinogenesis
Catheter Ablation
Female
Radiology
medicine.symptom
Tomography, X-Ray Computed
business
Subjects
Details
- ISSN :
- 14321084 and 09387994
- Volume :
- 31
- Database :
- OpenAIRE
- Journal :
- European Radiology
- Accession number :
- edsair.doi.dedup.....c46dc897129d52c07790028b687024af
- Full Text :
- https://doi.org/10.1007/s00330-021-07774-4