Back to Search
Start Over
Validation of the physical and RBE-weighted dose estimator based on PHITS coupled with a microdosimetric kinetic model for proton therapy
- Source :
- Journal of Radiation Research
- Publication Year :
- 2017
- Publisher :
- Oxford University Press (OUP), 2017.
-
Abstract
- The microdosimetric kinetic model (MKM) is widely used for estimating relative biological effectiveness (RBE)-weighted doses for various radiotherapies because it can determine the surviving fraction of irradiated cells based on only the lineal energy distribution, and it is independent of the radiation type and ion species. However, the applicability of the method to proton therapy has not yet been investigated thoroughly. In this study, we validated the RBE-weighted dose calculated by the MKM in tandem with the Monte Carlo code PHITS for proton therapy by considering the complete simulation geometry of the clinical proton beam line. The physical dose, lineal energy distribution, and RBE-weighted dose for a 155 MeV mono-energetic and spread-out Bragg peak (SOBP) beam of 60 mm width were evaluated. In estimating the physical dose, the calculated depth dose distribution by irradiating the mono-energetic beam using PHITS was consistent with the data measured by a diode detector. A maximum difference of 3.1% in the depth distribution was observed for the SOBP beam. In the RBE-weighted dose validation, the calculated lineal energy distributions generally agreed well with the published measurement data. The calculated and measured RBE-weighted doses were in excellent agreement, except at the Bragg peak region of the mono-energetic beam, where the calculation overestimated the measured data by ~15%. This research has provided a computational microdosimetric approach based on a combination of PHITS and MKM for typical clinical proton beams. The developed RBE-estimator function has potential application in the treatment planning system for various radiotherapies.
- Subjects :
- Proton
Health, Toxicology and Mutagenesis
Physics::Medical Physics
Sobp
Bragg peak
Radiation
030218 nuclear medicine & medical imaging
PHITS
microdosimetric kinetic model
03 medical and health sciences
0302 clinical medicine
relative biological effectiveness
Regular Paper
Proton Therapy
Relative biological effectiveness
Humans
Radiology, Nuclear Medicine and imaging
Irradiation
Proton therapy
Physics
Phantoms, Imaging
Radiochemistry
Reproducibility of Results
Dose-Response Relationship, Radiation
Models, Theoretical
Computational physics
Kinetics
030220 oncology & carcinogenesis
Beam (structure)
Subjects
Details
- ISSN :
- 13499157 and 04493060
- Volume :
- 59
- Database :
- OpenAIRE
- Journal :
- Journal of Radiation Research
- Accession number :
- edsair.doi.dedup.....c5f368d8fbf98b1d289c6d84142b403a
- Full Text :
- https://doi.org/10.1093/jrr/rrx057