Back to Search
Start Over
The optimal imaging window for dysplastic colorectal polyp detection using c-met-targeted fluorescence molecular endoscopy
- Source :
- Journal of Nuclear Medicine, 61(10), 1435-1441. SOC NUCLEAR MEDICINE INC, Journal of Nuclear Medicine, 61(10), 1435-1441. Society of Nuclear Medicine and Molecular Imaging
- Publication Year :
- 2020
-
Abstract
- Fluorescence molecular endoscopy (FME) is an emerging technique that has the potential to improve the 22% colorectal polyp detection miss-rate. We determined the optimal dose-to-imaging interval and safety of FME using EMI-137, a c-Met-targeted fluorescent peptide, in a population at high risk for colorectal cancer. Methods: We performed in vivo FME and quantification of fluorescence by multidiameter single-fiber reflectance/single-fiber fluorescence spectroscopy in 15 patients with a dysplastic colorectal adenoma. EMI-137 was intravenously administered (0.13 mg/kg) at a 1-, 2- or 3-h dose-to-imaging interval (n = 3 patients per cohort). Two cohorts were expanded to 6 patients on the basis of target-to-background ratios. Fluorescence was correlated to histopathology and c-Met expression. EMI-137 binding specificity was assessed by fluorescence microscopy and in vitro experiments. Results: FME using EMI-137 appeared to be safe and well tolerated. All dose-to-imaging intervals showed significantly higher fluorescence in the colorectal lesions than in surrounding tissue, with a target-to-background ratio of 1.53, 1.66, and 1.74 for the 1-, 2-, and 3-h cohorts, respectively, and a mean intrinsic fluorescence of 0.035 vs. 0.023 mm-1 (P < 0.0003), 0.034 vs. 0.021 mm-1 (P < 0.0001), and 0.033 vs. 0.019 mm-1 (P < 0.0001), respectively. Fluorescence correlated with histopathology on a macroscopic and microscopic level, with significant c-Met overexpression in dysplastic mucosa. In vitro, a dose-dependent specific binding was confirmed. Conclusion: FME using EMI-137 appeared to be safe and feasible within a 1- to 3-h dose-to-imaging interval. No clinically significant differences were observed among the cohorts, although a 1-h dose-to-imaging interval was preferred from a clinical perspective. Future studies will investigate EMI-137 for improved colorectal polyp detection during screening colonoscopies.
- Subjects :
- Adenoma
Male
medicine.medical_specialty
Colorectal cancer
Population
Colonic Polyps
colorectal cancer
Colorectal adenoma
Gastroenterology
Fluorescence spectroscopy
03 medical and health sciences
0302 clinical medicine
In vivo
Internal medicine
EMI-137 targeting c-Met
Fluorescence microscope
medicine
Humans
Radiology, Nuclear Medicine and imaging
fluorescence molecular endoscopy
education
030304 developmental biology
Aged
colorectal polyp detection
0303 health sciences
education.field_of_study
business.industry
Colonoscopy
Middle Aged
Proto-Oncogene Proteins c-met
medicine.disease
optimal imaging window
Spectrometry, Fluorescence
Colorectal Polyp
030211 gastroenterology & hepatology
Histopathology
Female
business
Colorectal Neoplasms
HT29 Cells
Subjects
Details
- Language :
- English
- ISSN :
- 01615505
- Database :
- OpenAIRE
- Journal :
- Journal of Nuclear Medicine, 61(10), 1435-1441. SOC NUCLEAR MEDICINE INC, Journal of Nuclear Medicine, 61(10), 1435-1441. Society of Nuclear Medicine and Molecular Imaging
- Accession number :
- edsair.doi.dedup.....c611f0f8192fd3ae64d20e23297406e9
- Full Text :
- https://doi.org/10.2967/jnumed.119.238790