Back to Search
Start Over
Selvester score predicts implantable cardioverter defibrillator shocks in patients with non‐ischemic cardiomyopathy
- Source :
- Journal of Arrhythmia, Vol 37, Iss 4, Pp 1046-1051 (2021), Journal of Arrhythmia
- Publication Year :
- 2021
- Publisher :
- Wiley, 2021.
-
Abstract
- Background The implantable cardiac defibrillator is the cornerstone of prevention of sudden cardiac death in non‐ischemic cardiomyopathy. The Selvester score, which is frequently investigated in ischemic cardiomyopathy, has not been investigated in the field of non‐ischemic cardiomyopathy. Aim The aim of this study was to evaluate the Selvester score for determining appropriate implantable cardiac defibrillator shocks in non‐ischemic cardiomyopathy patients. Materials and methods In all, 131 non‐ischemic cardiomyopathy patients were included in the study. A simplified Selvester score was calculated from ECG data. Patients were divided into two groups according to whether they received ICD shock. Results Of the patients, 28.2% received appropriate implantable cardiac defibrillator shock. The Selvester score was significantly higher in patients receiving appropriate shock when compared to patients with no implantable cardiac defibrillator shocks (8.8 ± 4.6 vs 7.2 ± 3.3, P = .040). The median QRS duration was significantly longer in patients receiving appropriate shock than in patients with no shocks (130.14 ± 35.08 ms vs 120.12 ± 20.57 ms, P = .045). We determined that the cutoff value for the Selvester score to predict ICD shocks was 6.5 with a sensitivity of 72.0% and a specificity of 83% (AUC = 0.717; %95 GA: 0.627‐0.807, P<br />Selvester score was higher in patients receiving appropriate shock than in patients who did not recieve any implantable cardiac defibrillator shock. In the selection of patients undergoing implantable cardioverter defibrillator for primer prevention of sudden cardiac death with nonischemic cardiomyopathy, the Selvester score may be used in addition to left ventricular ejection fraction.
- Subjects :
- medicine.medical_specialty
medicine.medical_treatment
Cardiomyopathy
shock
Ventricular tachycardia
Sudden cardiac death
Median QRS Duration
Internal medicine
medicine
Diseases of the circulatory (Cardiovascular) system
non‐ischemic cardiomyopathy
Ischemic cardiomyopathy
business.industry
ICD
Original Articles
Implantable cardioverter-defibrillator
medicine.disease
Selvester score
RC666-701
Shock (circulatory)
Ventricular fibrillation
Cardiology
Original Article
medicine.symptom
Cardiology and Cardiovascular Medicine
business
Subjects
Details
- ISSN :
- 18832148 and 18804276
- Volume :
- 37
- Database :
- OpenAIRE
- Journal :
- Journal of Arrhythmia
- Accession number :
- edsair.doi.dedup.....c73809869e6efd3cdb7e7e862a0c7345
- Full Text :
- https://doi.org/10.1002/joa3.12571