Back to Search Start Over

Agreement between different input image types in brain atrophy measurement in multiple sclerosis using SIENAX and SIENA

Authors :
Veronica, Neacsu
Bas, Jasperse
Tijmen, Korteweg
Dirk L, Knol
Paola, Valsasina
Massimo, Filippi
Frederik, Barkhof
Marco, Rovaris
Hugo, Vrenken
A, Thompson
Neuroscience Campus Amsterdam 2008
Neacsu, V
Jasperse, B
Korteweg, T
Knol, Dl
Valsasina, P
Filippi, Massimo
Barkhof, F
Rovaris, M
Vrenken, H.
Neurology
Radiology and nuclear medicine
Epidemiology and Data Science
Source :
Neacsu, V, Jasperse, B, Korteweg, T, Knol, D L, Valsasina, P, Filippi, M, Barkhof, F, Rovaris, M, Vrenken, H & MAGNIMS Study Group 2008, ' Agreement between different input image types in brain atrophy measurement in multiple sclerosis using SIENAX and SIENA ', Journal of Magnetic Resonance Imaging, vol. 28, no. 3, pp. 559-565 . https://doi.org/10.1002/jmri.21501, Journal of Magnetic Resonance Imaging, 28(3), 559-565. John Wiley and Sons Inc., Neacsu, V, Jasperse, B, Korteweg, T, Knol, D L, Valsasina, P, Filippi, M, Barkhof, F, Rovaris, M & Vrenken, H 2008, ' Agreement between different input image types in brain atrophy measurement in multiple sclerosis using SIENAX and SIENA ', Journal of Magnetic Resonance Imaging, vol. 28, no. 3, pp. 559-565 . https://doi.org/10.1002/jmri.21501
Publication Year :
2008

Abstract

Purpose To investigate whether multiple sclerosis (MS) atrophy can be assessed by SIENA and SIENAX software using other image types from MS research protocols than T1-weighted images without contrast agent, which are not always available. Materials and Methods We selected 46 MS patients with identical magnetic resonance imaging (MRI) protocols at two timepoints. We calculated normalized brain volume (NBV) using SIENAX, and percentage brain volume change (PBVC) using SIENA, from T1-weighted images with and without contrast agent, T2-weighted images, and (calculated) pseudo-T1-weighted images. Relative agreement of the results was assessed using variance component estimation. Results Relative agreement with T1-weighted images without contrast agent was good for T1-weighted images with contrast agent (ICC = 0.86 for NBV, ICC = 0.77 for PBVC), and reasonably good for pseudo-T1 and T2-weighted images (T2: ICC = 0.72 for NBV, 0.58 for PBVC; pseudo-T1: ICC = 0.68 for NBV, 0.83 for PBVC). Conclusion Brain atrophy can be studied using SIENA and SIENAX if T1-weighted images without contrast agent are not available. T1-weighted images with contrast agent should be used if available. Otherwise, pseudo-T1 and T2-weighted images seem acceptable and accessible alternatives. The use of these other images will greatly improve research possibilities, especially regarding older datasets. J. Magn. Reson. Imaging 2008;28:559–565. © 2008 Wiley-Liss, Inc.

Details

Language :
English
ISSN :
10531807
Database :
OpenAIRE
Journal :
Neacsu, V, Jasperse, B, Korteweg, T, Knol, D L, Valsasina, P, Filippi, M, Barkhof, F, Rovaris, M, Vrenken, H & MAGNIMS Study Group 2008, ' Agreement between different input image types in brain atrophy measurement in multiple sclerosis using SIENAX and SIENA ', Journal of Magnetic Resonance Imaging, vol. 28, no. 3, pp. 559-565 . https://doi.org/10.1002/jmri.21501, Journal of Magnetic Resonance Imaging, 28(3), 559-565. John Wiley and Sons Inc., Neacsu, V, Jasperse, B, Korteweg, T, Knol, D L, Valsasina, P, Filippi, M, Barkhof, F, Rovaris, M & Vrenken, H 2008, ' Agreement between different input image types in brain atrophy measurement in multiple sclerosis using SIENAX and SIENA ', Journal of Magnetic Resonance Imaging, vol. 28, no. 3, pp. 559-565 . https://doi.org/10.1002/jmri.21501
Accession number :
edsair.doi.dedup.....c7b2aa15804146d48a31355e1ffea05b
Full Text :
https://doi.org/10.1002/jmri.21501