Back to Search Start Over

Intra-procedural monitoring protocol using routine transthoracic echocardiography with backup trans-oesophageal probe in transcatheter aortic valve replacement: a single centre experience

Authors :
Antonio Colombo
Francesco Ancona
Cristina Capogrosso
Andrea Fisicaro
Ottavio Alfieri
Alberto Margonato
Azeem Latib
Alessandro Castiglioni
Eustachio Agricola
Stefano Stella
Matteo Montorfano
Francesco Melillo
Stella, S
Melillo, F
Capogrosso, C
Fisicaro, A
Ancona, F
Latib, A
Montorfano, M
Colombo, A
Alfieri, O
Castiglioni, A
Margonato, A
Agricola, E
Source :
European heart journal. Cardiovascular Imaging. 21(1)
Publication Year :
2018

Abstract

Aim The aim of this study is to describe our 9-year experience in transcatheter aortic valve replacement (TAVR) using transthoracic echocardiography (TTE) as a routine intra-procedural imaging modality with trans-oesophageal echocardiography (TEE) as a backup. Methods and results From January 2008 to December 2017, 1218 patients underwent transfemoral TAVR at our Institution. Except the first 20 cases, all procedures have been performed under conscious sedation, with fluoroscopic guidance and TTE imaging monitoring. Once the TTE resulted suboptimal for final result assessment or a complication was either suspected or identified on TTE, TEE evaluation was promptly performed under general anaesthesia. Only 24 (1.9%) cases required a switch to TEE: 6 cases for suboptimal TTE prosthetic valve leak (PVL) quantification; 12 cases for haemodynamic instability; 2 cases for pericardial effusion without haemodynamic instability; 4 cases for urgent TAVR. The 30-days and 1-year all-cause mortality were 2.1% and 10.2%, respectively. Cardiac mortality at 30-days and 1-year follow-up were 0.6% and 4.1%, respectively. Intra-procedural and pre-discharge TT evaluation showed good agreement for PVL quantification (k agreement: 0.827, P = 0.005). Conclusion TTE monitoring seems a reasonable imaging tool for TAVR intra-procedural monitoring without delay in diagnosis of complications and a reliable paravalvular leak assessment. However, TEE is undoubtedly essential in identifying the exact mechanism in most of the complications.

Details

ISSN :
20472412
Volume :
21
Issue :
1
Database :
OpenAIRE
Journal :
European heart journal. Cardiovascular Imaging
Accession number :
edsair.doi.dedup.....c8237ca9e5b53824211bb0da92638d44