Evaluating the accuracy and large inaccuracy of two continuous glucose monitoring systems
- Source :
- Diabetes technologytherapeutics. 15(2)
- Publication Year :
- 2012
-
Abstract
- This study evaluated the accuracy and large inaccuracy of the Freestyle Navigator (FSN) (Abbott Diabetes Care, Alameda, CA) and Dexcom SEVEN PLUS (DSP) (Dexcom, Inc., San Diego, CA) continuous glucose monitoring (CGM) systems during closed-loop studies.Paired CGM and plasma glucose values (7,182 data pairs) were collected, every 15-60 min, from 32 adults (36.2±9.3 years) and 20 adolescents (15.3±1.5 years) with type 1 diabetes who participated in closed-loop studies. Levels 1, 2, and 3 of large sensor error with increasing severity were defined according to absolute relative deviation greater than or equal to ±40%, ±50%, and ±60% at a reference glucose level of ≥6 mmol/L or absolute deviation greater than or equal to ±2.4 mmol/L,±3.0 mmol/L, and ±3.6 mmol/L at a reference glucose level of6 mmol/L.Median absolute relative deviation was 9.9% for FSN and 12.6% for DSP. Proportions of data points in Zones A and B of Clarke error grid analysis were similar (96.4% for FSN vs. 97.8% for DSP). Large sensor over-reading, which increases risk of insulin over-delivery and hypoglycemia, occurred two- to threefold more frequently with DSP than FSN (once every 2.5, 4.6, and 10.7 days of FSN use vs. 1.2, 2.0, and 3.7 days of DSP use for Level 1-3 errors, respectively). At levels 2 and 3, large sensor errors lasting 1 h or longer were absent with FSN but persisted with DSP.FSN and DSP differ substantially in the frequency and duration of large inaccuracy despite only modest differences in conventional measures of numerical and clinical accuracy. Further evaluations are required to confirm that FSN is more suitable for integration into closed-loop delivery systems.
- Subjects :
- Adult
Blood Glucose
Male
medicine.medical_specialty
Adolescent
Endocrinology, Diabetes and Metabolism
Grid analysis
Relative standard deviation
030209 endocrinology & metabolism
03 medical and health sciences
0302 clinical medicine
Endocrinology
Animal science
Drug Delivery Systems
Insulin Infusion Systems
Internal medicine
medicine
Humans
Hypoglycemic Agents
Insulin
030212 general & internal medicine
Retrospective Studies
Plasma glucose
business.industry
Continuous glucose monitoring
Blood Glucose Self-Monitoring
Reproducibility of Results
Equipment Design
Original Articles
Absolute deviation
Self Care
Medical Laboratory Technology
Diabetes Mellitus, Type 1
Multicenter study
England
Self care
Female
business
Subjects
Details
- ISSN :
- 15578593
- Volume :
- 15
- Issue :
- 2
- Database :
- OpenAIRE
- Journal :
- Diabetes technologytherapeutics
- Accession number :
- edsair.doi.dedup.....c82e9460defd3727ce7de12af32dbdc7