Back to Search
Start Over
Effect of Localizer Radiography Projection on Organ Dose at Chest CT with Automatic Tube Current Modulation
- Source :
- Radiology. 282(3)
- Publication Year :
- 2016
-
Abstract
- Purpose To calculate the effect of localizer radiography projections to the total radiation dose, including both the dose from localizer radiography and that from subsequent chest computed tomography (CT) with tube current modulation (TCM). Materials and Methods An anthropomorphic phantom was scanned with 192-section CT without and with differently sized breast attachments. Chest CT with TCM was performed after one localizer radiographic examination with anteroposterior (AP) or posteroanterior (PA) projections. Dose distributions were obtained by means of Monte Carlo simulations based on acquired CT data. For Monte Carlo simulations of localizer radiography, the tube position was fixed at 0° and 180°; for chest CT, a spiral trajectory with TCM was used. The effect of tube start angles on dose distribution was investigated with Monte Carlo simulations by using TCM curves with fixed start angles (0°, 90°, and 180°). Total doses for lungs, heart, and breast were calculated as the sum of the dose from localizer radiography and CT. Image noise was defined as the standard deviation of attenuation measured in 14 circular regions of interest. The Wilcoxon signed rank test, paired t test, and Friedman analysis of variance were conducted to evaluate differences in noise, TCM curves, and organ doses, respectively. Results Organ doses from localizer radiography were lower when using a PA instead of an AP projection (P = .005). The use of a PA projection resulted in higher TCM values for chest CT (P.001) owing to the higher attenuation (P.001) and thus resulted in higher total organ doses for all investigated phantoms and protocols (P.001). Noise in CT images was lower with PA localizer radiography than with AP localizer radiography (P = .03). The use of an AP projection allowed for total dose reductions of 16%, 15%, and 12% for lungs, breast, and heart, respectively. Differences in organ doses were not related to tube start angles (P = .17). Conclusion The total organ doses are higher when using PA projection localizer radiography owing to higher TCM values, whereas the organ doses from PA localizer radiography alone are lower. Thus, PA localizer radiography should be used in combination with reduced reference tube current at subsequent chest CT.
- Subjects :
- medicine.medical_specialty
business.industry
10042 Clinic for Diagnostic and Interventional Radiology
Phantoms, Imaging
Radiography
Chest ct
610 Medicine & health
Radiation Dosage
030218 nuclear medicine & medical imaging
03 medical and health sciences
0302 clinical medicine
030220 oncology & carcinogenesis
Tube current modulation
Image Interpretation, Computer-Assisted
medicine
2741 Radiology, Nuclear Medicine and Imaging
Humans
Radiology, Nuclear Medicine and imaging
Radiography, Thoracic
Radiology
Tomography
business
Projection (set theory)
Nuclear medicine
Tomography, X-Ray Computed
Subjects
Details
- ISSN :
- 15271315
- Volume :
- 282
- Issue :
- 3
- Database :
- OpenAIRE
- Journal :
- Radiology
- Accession number :
- edsair.doi.dedup.....c9bf7819ddfc4c0b7b27ee8aaa754d9a