Back to Search Start Over

FMX - the Frontier Microfocusing Macromolecular Crystallography Beamline at the National Synchrotron Light Source II

Authors :
Kun Qian
Jean Jakoncic
Jun Aishima
Dileep Bhogadi
John Lara
Wuxian Shi
Mourad Idir
Edwin Lazo
Oleg Chubar
Sean McSweeney
Bruno Martins
Stuart Myers
Robert M. Sweet
Yuan Gao
Martin Fuchs
Thomas Langdon
Lei Huang
Herbert J. Bernstein
John M. Skinner
Babak Andi
Grace Shea-McCarthy
Lonny E. Berman
Dieter K. Schneider
Source :
J Synchrotron Radiat
Publication Year :
2020

Abstract

Two new macromolecular crystallography (MX) beamlines at the National Synchrotron Light Source II, FMX and AMX, opened for general user operation in February 2017 [Schneider et al. (2013). J. Phys. Conf. Ser. 425, 012003; Fuchs et al. (2014). J. Phys. Conf. Ser. 493, 012021; Fuchs et al. (2016). AIP Conf. Proc. SRI2015, 1741, 030006]. FMX, the micro-focusing Frontier MX beamline in sector 17-ID-2 at NSLS-II, covers a 5–30 keV photon energy range and delivers a flux of 4.0 × 1012 photons s−1 at 1 Å into a 1 µm × 1.5 µm to 10 µm × 10 µm (V × H) variable focus, expected to reach 5 × 1012 photons s−1 at final storage-ring current. This flux density surpasses most MX beamlines by nearly two orders of magnitude. The high brightness and microbeam capability of FMX are focused on solving difficult crystallographic challenges. The beamline's flexible design supports a wide range of structure determination methods – serial crystallography on micrometre-sized crystals, raster optimization of diffraction from inhomogeneous crystals, high-resolution data collection from large-unit-cell crystals, room-temperature data collection for crystals that are difficult to freeze and for studying conformational dynamics, and fully automated data collection for sample-screening and ligand-binding studies. FMX's high dose rate reduces data collection times for applications like serial crystallography to minutes rather than hours. With associated sample lifetimes as short as a few milliseconds, new rapid sample-delivery methods have been implemented, such as an ultra-high-speed high-precision piezo scanner goniometer [Gao et al. (2018). J. Synchrotron Rad. 25, 1362–1370], new microcrystal-optimized micromesh well sample holders [Guo et al. (2018). IUCrJ, 5, 238–246] and highly viscous media injectors [Weierstall et al. (2014). Nat. Commun. 5, 3309]. The new beamline pushes the frontier of synchrotron crystallography and enables users to determine structures from difficult-to-crystallize targets like membrane proteins, using previously intractable crystals of a few micrometres in size, and to obtain quality structures from irregular larger crystals.

Details

ISSN :
16005775
Volume :
28
Issue :
Pt 2
Database :
OpenAIRE
Journal :
Journal of synchrotron radiation
Accession number :
edsair.doi.dedup.....ca66808b4f41fce9163d525fdc37bcfd