Back to Search
Start Over
Real-time intraocular pressure measurement in standard and microcoaxial phacoemulsification
- Source :
- Journal of Cataract and Refractive Surgery. 36:53-57
- Publication Year :
- 2010
- Publisher :
- Ovid Technologies (Wolters Kluwer Health), 2010.
-
Abstract
- To evaluate intraocular pressure (IOP) in the vitreous cavity during various stages of cataract surgery.University Eye Hospital, Ludwig-Maximilians University, Munich, Germany.In consecutive eyes having combined phacoemulsification, intraocular lens implantation, and pars plana vitrectomy, IOP was monitored in real time through a 25-gauge pars plana cannula connected to an external pressure transducer. Surgery was performed by standard clear corneal phacoemulsification with a 2.5 mm incision and a Mega-Tip (1.26 mm aperture) (Group 1) or by microcoaxial phacoemulsification with a CMP-Tip (0.80 mm aperture) (Group 2).The 2 groups had 5 eyes each. The mean IOP in Group 1 and in Group 2, respectively, was 15.9 mm Hg +/- 9.5 (SD) and 17.0 +/- 13.5 mm Hg preoperatively (P = .442), 40.1 +/- 12.7 mm Hg and 36.5 +/- 17.2 mm Hg during lens removal (P.001), 17.6 +/- 14.2 mm Hg and 22.6 +/- 8.6 mm Hg during irrigation/aspiration (P.001), 13.3 +/- 13.2 mm Hg and 16.3 +/- 13.1 mm Hg during IOL implantation (P = .005), and 22.9 +/- 7.0 mm Hg and 21.5 +/- 10.0 mm Hg after IOL implantation through the end of surgery (P = .329).Although the IOP levels were significantly lower than those in previous studies, both phacoemulsification techniques had safe IOP profiles during various steps of surgery. Real-time IOP monitoring may prevent the surgeon from inducing excessive IOP elevation during intraocular manipulation.No author has a financial or proprietary interest in any material or method mentioned.
- Subjects :
- Male
Pars plana
Microsurgery
medicine.medical_specialty
Intraocular pressure
genetic structures
medicine.medical_treatment
Vitrectomy
Intraocular lens
Lens Implantation, Intraocular
Retinal Diseases
Computer Systems
Ophthalmology
Transducers, Pressure
medicine
Humans
Intraocular Pressure
Aged
Retrospective Studies
Aged, 80 and over
Phacoemulsification
business.industry
Middle Aged
Cataract surgery
Cannula
eye diseases
Sensory Systems
Surgery
medicine.anatomical_structure
Sclerostomy
Female
sense organs
business
Subjects
Details
- ISSN :
- 08863350
- Volume :
- 36
- Database :
- OpenAIRE
- Journal :
- Journal of Cataract and Refractive Surgery
- Accession number :
- edsair.doi.dedup.....cd7782f0dd004fe3d7171d04b8875f84
- Full Text :
- https://doi.org/10.1016/j.jcrs.2009.07.035