Back to Search
Start Over
Computer-assisted screw insertion into the first sacral vertebra using a three-dimensional image intensifier: results of a controlled experimental investigation
- Source :
- European Spine Journal. 15:757-763
- Publication Year :
- 2005
- Publisher :
- Springer Science and Business Media LLC, 2005.
-
Abstract
- Currently there are few data available regarding the application and efficacy of computer-assisted procedures in the sacral spine. In order to optimize and standardize this procedure, a controlled experimental investigation has been performed. The aim of the study is to systematically assess the efficacy of a novel three-dimensional image intensifier used for navigated transiliac screw insertion into the first sacral vertebra. Screws were inserted iliosacrally into the first sacral vertebra of preserved human cadaver specimens. The instrument navigated procedure was performed with the "Siremobil Iso-C(3D) " (Siemens Medical Solutions) and the "Navigation System" by Stryker. The accuracy and quality of the imaging procedure as well as the fluoroscopic exposure times were measured. These results were compared to three control groups (CT-based navigation, C-arm navigation, and fluoroscopic guidance). In each group a total amount of 20 screws was implanted. Screw position was postoperatively assessed by Iso-C(3D) or CT-scan. The navigated procedure using the Iso-C(3D) provided good feasibility characteristics without requiring a specific matching process. It revealed the shortest procedure time of all navigated procedures and significantly decreased fluoroscopic time compared to C-arm navigation and fluoroscopic guidance. Furthermore, Iso-C(3D) navigation showed no screw malposition and was in this regard superior to C-arm navigated and fluoroscopic guided procedures. The quality of imaging was sufficient for accurate placement, but did not share the high-resolution level of CT-based navigation. These findings indicate that application of the Iso-C(3D) for navigated transiliac screw insertion into S1 can be recommended as a feasible and safe technique, enabling the surgeon to reduce procedure and fluoroscopic time. Further progress in improving the quality of the Iso-C(3D) image should be attempted.
- Subjects :
- Sacrum
medicine.medical_specialty
medicine.medical_treatment
Bone Screws
law.invention
Imaging, Three-Dimensional
Sacral Vertebra
law
Cadaver
medicine
Humans
Fluoroscopy
X-Ray Intensifying Screens
Orthopedics and Sports Medicine
Computer-assisted surgery
medicine.diagnostic_test
business.industry
Navigation system
Image intensifier
Surgery, Computer-Assisted
Original Article
Surgery
Radiology
Tomography
Tomography, X-Ray Computed
Nuclear medicine
business
Subjects
Details
- ISSN :
- 14320932 and 09406719
- Volume :
- 15
- Database :
- OpenAIRE
- Journal :
- European Spine Journal
- Accession number :
- edsair.doi.dedup.....cf0cd08f083af12714ace5de58af4aa0
- Full Text :
- https://doi.org/10.1007/s00586-005-0992-5