Back to Search
Start Over
Effect of varying injection rates of a saline chaser on aortic enhancement in CT angiography: phantom study
- Source :
- Schindera, Sebastian T; Nelson, Rendon C; Howle, Laurens; Nichols, Eli; DeLong, David M; Merkle, Elmar M (2008). Effect of varying injection rates of a saline chaser on aortic enhancement in CT angiography: phantom study. European radiology, 18(8), pp. 1683-9. Berlin: Springer-Verlag 10.1007/s00330-008-0911-3
- Publication Year :
- 2008
- Publisher :
- Springer-Verlag, 2008.
-
Abstract
- The effect of varying injection rates of a saline chaser on aortic enhancement in computed tomography (CT) angiography was determined. Single-level, dynamic CT images of a physiological flow phantom were acquired between 0 and 50 s after initiation of contrast medium injection. Four injection protocols were applied with identical contrast medium administration (150 ml injected at 5 ml/s). For baseline protocol A, no saline chaser was applied. For protocols B, C, and D, 50 ml of saline was injected at 2.5 ml/s, 5 ml/s, and 10 ml/s, respectively. Injecting the saline chaser at twice the rate as the contrast medium yielded significantly higher peak aortic enhancement values than injecting the saline at half or at the same rate as the contrast medium (P < 0.05). Average peak aortic enhancement (HU) measured 214, 214, 218, and 226 for protocols A, B, C, and D, respectively. The slower the saline-chaser injection rate, the longer the duration of 90% peak enhancement: 13.6, 12.2, and 11.7 s for protocols B, C, and D, respectively (P > 0.05). In CT angiography, saline chaser injected at twice the rate as the contrast medium leads to increased peak aortic enhancement and saline chaser injected at half the rate tends towards prolonging peak aortic enhancement plateau.
- Subjects :
- medicine.medical_specialty
medicine.medical_treatment
Contrast Media
Computed tomography
Sodium Chloride
Aortography
Sensitivity and Specificity
Imaging phantom
Drug Administration Schedule
Medicine
Humans
Radiology, Nuclear Medicine and imaging
Saline
medicine.diagnostic_test
business.industry
Phantoms, Imaging
Ultrasound
Angiography
Reproducibility of Results
General Medicine
Iopamidol
Radiographic Image Enhancement
Contrast medium
Physiological flow
Radiology
Dynamic ct
business
Tomography, X-Ray Computed
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Journal :
- Schindera, Sebastian T; Nelson, Rendon C; Howle, Laurens; Nichols, Eli; DeLong, David M; Merkle, Elmar M (2008). Effect of varying injection rates of a saline chaser on aortic enhancement in CT angiography: phantom study. European radiology, 18(8), pp. 1683-9. Berlin: Springer-Verlag 10.1007/s00330-008-0911-3 <http://dx.doi.org/10.1007/s00330-008-0911-3>
- Accession number :
- edsair.doi.dedup.....cf828274a6e70730ab03125129b147b1
- Full Text :
- https://doi.org/10.7892/boris.26265